mirror of
https://github.com/netbirdio/advisory-database.git
synced 2026-05-22 18:04:22 -07:00
Publish Advisories
GHSA-3hx6-3qqx-qhvf GHSA-75ww-mcr4-2298 GHSA-8745-q6hh-2437 GHSA-fwhw-h3p7-gx3q GHSA-mm7h-5pr2-rrfg
This commit is contained in:
@@ -0,0 +1,40 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-3hx6-3qqx-qhvf",
|
||||
"modified": "2025-03-19T03:30:35Z",
|
||||
"published": "2025-03-19T03:30:35Z",
|
||||
"aliases": [
|
||||
"CVE-2024-10441"
|
||||
],
|
||||
"details": "Improper encoding or escaping of output vulnerability in the system plugin daemon in Synology BeeStation Manager (BSM) before 1.1-65374, Synology DiskStation Manager (DSM) before 6.2.4-25556-8, 7.1.1-42962-7, 7.2-64570-4, 7.2.1-69057-6 and 7.2.2-72806-1 and Synology Unified Controller (DSMUC) before 3.1.4-23079 allows remote attackers to execute arbitrary code via unspecified vectors.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-10441"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_24_20"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_24_23"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-116"
|
||||
],
|
||||
"severity": "CRITICAL",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-19T02:15:27Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-75ww-mcr4-2298",
|
||||
"modified": "2025-03-19T03:30:35Z",
|
||||
"published": "2025-03-19T03:30:35Z",
|
||||
"aliases": [
|
||||
"CVE-2024-11131"
|
||||
],
|
||||
"details": "A vulnerability regarding out-of-bounds read is found in the video interface. This allows remote attackers to execute arbitrary code via unspecified vectors. The following models with Synology Camera Firmware versions before 1.2.0-0525 may be affected: BC500, CC400W and TC500.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-11131"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_24_24"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-125"
|
||||
],
|
||||
"severity": "CRITICAL",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-19T03:15:12Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-8745-q6hh-2437",
|
||||
"modified": "2025-03-19T03:30:35Z",
|
||||
"published": "2025-03-19T03:30:35Z",
|
||||
"aliases": [
|
||||
"CVE-2024-10442"
|
||||
],
|
||||
"details": "Off-by-one error vulnerability in the transmission component in Synology Replication Service before 1.0.12-0066, 1.2.2-0353 and 1.3.0-0423 and Synology Unified Controller (DSMUC) before 3.1.4-23079 allows remote attackers to execute arbitrary code, potentially leading to a broader impact across the system via unspecified vectors.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-10442"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_24_22"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-193"
|
||||
],
|
||||
"severity": "CRITICAL",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-19T03:15:11Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,40 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-fwhw-h3p7-gx3q",
|
||||
"modified": "2025-03-19T03:30:35Z",
|
||||
"published": "2025-03-19T03:30:35Z",
|
||||
"aliases": [
|
||||
"CVE-2024-10445"
|
||||
],
|
||||
"details": "Improper certificate validation vulnerability in the update functionality in Synology BeeStation Manager (BSM) before 1.1-65374, Synology DiskStation Manager (DSM) before 6.2.4-25556-8, 7.1.1-42962-7, 7.2-64570-4, 7.2.1-69057-6 and 7.2.2-72806-1 and Synology Unified Controller (DSMUC) before 3.1.4-23079 allows remote attackers to write limited files via unspecified vectors.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-10445"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_24_20"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_24_23"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-295"
|
||||
],
|
||||
"severity": "MODERATE",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-19T02:15:28Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-mm7h-5pr2-rrfg",
|
||||
"modified": "2025-03-19T03:30:35Z",
|
||||
"published": "2025-03-19T03:30:35Z",
|
||||
"aliases": [
|
||||
"CVE-2024-10444"
|
||||
],
|
||||
"details": "Improper certificate validation vulnerability in the LDAP utilities in Synology DiskStation Manager (DSM) before 7.1.1-42962-8, 7.2.1-69057-7 and 7.2.2-72806-3 allows man-in-the-middle attackers to hijack the authentication of administrators via unspecified vectors.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-10444"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_25_01"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-295"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-19T02:15:28Z"
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user