mirror of
https://github.com/netbirdio/advisory-database.git
synced 2026-05-22 18:04:22 -07:00
Publish Advisories
GHSA-5v9q-jpv7-7w2m GHSA-fh83-6qjg-wh4v GHSA-gjhg-f944-56m2 GHSA-j5vp-q6vg-25mf GHSA-pw5w-rmc5-f87r GHSA-r5j3-c4vg-xf85
This commit is contained in:
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-5v9q-jpv7-7w2m",
|
||||
"modified": "2025-03-10T09:31:49Z",
|
||||
"published": "2025-03-10T09:31:49Z",
|
||||
"aliases": [
|
||||
"CVE-2025-27257"
|
||||
],
|
||||
"details": "Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware.\nThe firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration check to be bypassed.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-27257"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-345"
|
||||
],
|
||||
"severity": "MODERATE",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-10T09:15:11Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-fh83-6qjg-wh4v",
|
||||
"modified": "2025-03-10T09:31:48Z",
|
||||
"published": "2025-03-10T09:31:48Z",
|
||||
"aliases": [
|
||||
"CVE-2025-27255"
|
||||
],
|
||||
"details": "Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-27255"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-798"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-10T09:15:11Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-gjhg-f944-56m2",
|
||||
"modified": "2025-03-10T09:31:48Z",
|
||||
"published": "2025-03-10T09:31:48Z",
|
||||
"aliases": [
|
||||
"CVE-2025-27256"
|
||||
],
|
||||
"details": "Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-27256"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-306"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-10T09:15:11Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-j5vp-q6vg-25mf",
|
||||
"modified": "2025-03-10T09:31:48Z",
|
||||
"published": "2025-03-10T09:31:48Z",
|
||||
"aliases": [
|
||||
"CVE-2025-27253"
|
||||
],
|
||||
"details": "An improper input validation in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that enstablishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-27253"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-20"
|
||||
],
|
||||
"severity": "MODERATE",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-10T09:15:10Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-pw5w-rmc5-f87r",
|
||||
"modified": "2025-03-10T09:31:48Z",
|
||||
"published": "2025-03-10T09:31:48Z",
|
||||
"aliases": [
|
||||
"CVE-2025-27254"
|
||||
],
|
||||
"details": "Improper Authentication vulnerability in GE Vernova EnerVista UR Setup allows Authentication Bypass. \nThe software's startup authentication can be disabled by altering a Windows registry setting that any user can modify.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-27254"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-287"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-10T09:15:11Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,40 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-r5j3-c4vg-xf85",
|
||||
"modified": "2025-03-10T09:31:48Z",
|
||||
"published": "2025-03-10T09:31:48Z",
|
||||
"aliases": [
|
||||
"CVE-2025-2150"
|
||||
],
|
||||
"details": "The C&Cm@il from HGiga has a Stored Cross-Site Scripting (XSS) vulnerability, allowing remote attackers with regular privileges to send emails containing malicious JavaScript code, which will be executed in the recipient's browser when they view the email.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N"
|
||||
}
|
||||
],
|
||||
"affected": [],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-2150"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.twcert.org.tw/en/cp-139-10005-05e0f-2.html"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.twcert.org.tw/tw/cp-132-10004-99474-1.html"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-79"
|
||||
],
|
||||
"severity": "MODERATE",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2025-03-10T08:15:11Z"
|
||||
}
|
||||
}
|
||||
Reference in New Issue