mirror of
https://github.com/netbirdio/advisory-database.git
synced 2026-05-22 18:04:22 -07:00
Publish Advisories
GHSA-57rv-qg24-x8hj GHSA-xj35-rhxx-w86c GHSA-7932-gcjg-wrfw GHSA-9fqj-q497-4x32 GHSA-cgvw-jh5j-mgq3 GHSA-f3qc-f3rx-3hrm GHSA-mw9x-2qwv-599p GHSA-qp96-9hxv-3xx4
This commit is contained in:
@@ -1,14 +1,17 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-57rv-qg24-x8hj",
|
||||
"modified": "2022-05-24T19:05:03Z",
|
||||
"modified": "2024-11-24T15:31:37Z",
|
||||
"published": "2022-05-24T19:05:03Z",
|
||||
"aliases": [
|
||||
"CVE-2021-22764"
|
||||
],
|
||||
"details": "A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.",
|
||||
"severity": [
|
||||
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L"
|
||||
}
|
||||
],
|
||||
"affected": [
|
||||
|
||||
@@ -18,6 +21,14 @@
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22764"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-159-02.pdf"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02%2Chttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02,http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
|
||||
|
||||
@@ -1,14 +1,17 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-xj35-rhxx-w86c",
|
||||
"modified": "2022-05-24T19:05:03Z",
|
||||
"modified": "2024-11-24T15:31:37Z",
|
||||
"published": "2022-05-24T19:05:03Z",
|
||||
"aliases": [
|
||||
"CVE-2021-22763"
|
||||
],
|
||||
"details": "A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.",
|
||||
"severity": [
|
||||
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
|
||||
}
|
||||
],
|
||||
"affected": [
|
||||
|
||||
@@ -18,6 +21,14 @@
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22763"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-159-02.pdf"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02%2Chttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02,http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-7932-gcjg-wrfw",
|
||||
"modified": "2024-11-11T09:30:42Z",
|
||||
"modified": "2024-11-24T15:31:38Z",
|
||||
"published": "2024-11-11T09:30:42Z",
|
||||
"aliases": [
|
||||
"CVE-2024-11068"
|
||||
@@ -21,6 +21,10 @@
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-11068"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.bleepingcomputer.com/news/security/d-link-wont-fix-critical-bug-in-60-000-exposed-eol-modems"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.twcert.org.tw/en/cp-139-8234-0514c-2.html"
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-9fqj-q497-4x32",
|
||||
"modified": "2024-11-11T09:30:42Z",
|
||||
"modified": "2024-11-24T15:31:38Z",
|
||||
"published": "2024-11-11T09:30:42Z",
|
||||
"aliases": [
|
||||
"CVE-2024-11066"
|
||||
@@ -21,6 +21,10 @@
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-11066"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.bleepingcomputer.com/news/security/d-link-wont-fix-critical-bug-in-60-000-exposed-eol-modems"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.twcert.org.tw/en/cp-139-8232-5d94e-2.html"
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-cgvw-jh5j-mgq3",
|
||||
"modified": "2024-11-19T18:30:59Z",
|
||||
"modified": "2024-11-24T15:31:38Z",
|
||||
"published": "2024-11-18T18:30:58Z",
|
||||
"aliases": [
|
||||
"CVE-2024-9474"
|
||||
@@ -28,6 +28,10 @@
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://security.paloaltonetworks.com/CVE-2024-9474"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://unit42.paloaltonetworks.com/cve-2024-0012-cve-2024-9474"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-f3qc-f3rx-3hrm",
|
||||
"modified": "2024-11-11T09:30:42Z",
|
||||
"modified": "2024-11-24T15:31:38Z",
|
||||
"published": "2024-11-11T09:30:42Z",
|
||||
"aliases": [
|
||||
"CVE-2024-11067"
|
||||
@@ -21,6 +21,10 @@
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-11067"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.bleepingcomputer.com/news/security/d-link-wont-fix-critical-bug-in-60-000-exposed-eol-modems"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.twcert.org.tw/en/cp-139-8233-903d9-2.html"
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-mw9x-2qwv-599p",
|
||||
"modified": "2024-11-19T18:30:59Z",
|
||||
"modified": "2024-11-24T15:31:38Z",
|
||||
"published": "2024-11-18T18:30:58Z",
|
||||
"aliases": [
|
||||
"CVE-2024-0012"
|
||||
@@ -28,6 +28,10 @@
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://security.paloaltonetworks.com/CVE-2024-0012"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://unit42.paloaltonetworks.com/cve-2024-0012-cve-2024-9474"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-qp96-9hxv-3xx4",
|
||||
"modified": "2024-11-06T15:30:40Z",
|
||||
"modified": "2024-11-24T15:31:37Z",
|
||||
"published": "2024-11-06T15:30:40Z",
|
||||
"aliases": [
|
||||
"CVE-2024-10914"
|
||||
@@ -41,6 +41,10 @@
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?submit.432847"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.bleepingcomputer.com/news/security/d-link-wont-fix-critical-flaw-affecting-60-000-older-nas-devices"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.dlink.com"
|
||||
@@ -48,7 +52,8 @@
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-707"
|
||||
"CWE-707",
|
||||
"CWE-74"
|
||||
],
|
||||
"severity": "CRITICAL",
|
||||
"github_reviewed": false,
|
||||
|
||||
Reference in New Issue
Block a user