mirror of
https://github.com/netbirdio/advisory-database.git
synced 2026-05-22 18:04:22 -07:00
Publish Advisories
GHSA-5c67-j7mc-2w23 GHSA-6gcp-m839-5fw4 GHSA-76x3-rw7v-gwwh GHSA-p3cw-2qg8-ghqq
This commit is contained in:
@@ -0,0 +1,58 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-5c67-j7mc-2w23",
|
||||
"modified": "2024-10-13T18:30:45Z",
|
||||
"published": "2024-10-13T18:30:45Z",
|
||||
"aliases": [
|
||||
"CVE-2024-9911"
|
||||
],
|
||||
"details": "A vulnerability was found in D-Link DIR-619L B1 2.06. It has been classified as critical. This affects the function formSetPortTr of the file /goform/formSetPortTr. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
|
||||
},
|
||||
{
|
||||
"type": "CVSS_V4",
|
||||
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X"
|
||||
}
|
||||
],
|
||||
"affected": [
|
||||
|
||||
],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-9911"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/D-Link/DIR-619L/formSetPortTr.md"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?ctiid.280239"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?id.280239"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?submit.418742"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.dlink.com"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-120"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2024-10-13T16:15:02Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,58 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-6gcp-m839-5fw4",
|
||||
"modified": "2024-10-13T18:30:45Z",
|
||||
"published": "2024-10-13T18:30:45Z",
|
||||
"aliases": [
|
||||
"CVE-2024-9913"
|
||||
],
|
||||
"details": "A vulnerability was found in D-Link DIR-619L B1 2.06. It has been rated as critical. This issue affects the function formSetRoute of the file /goform/formSetRoute. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
|
||||
},
|
||||
{
|
||||
"type": "CVSS_V4",
|
||||
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X"
|
||||
}
|
||||
],
|
||||
"affected": [
|
||||
|
||||
],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-9913"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/D-Link/DIR-619L/formSetRoute.md"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?ctiid.280241"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?id.280241"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?submit.418745"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.dlink.com"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-120"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2024-10-13T18:15:02Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,58 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-76x3-rw7v-gwwh",
|
||||
"modified": "2024-10-13T18:30:45Z",
|
||||
"published": "2024-10-13T18:30:45Z",
|
||||
"aliases": [
|
||||
"CVE-2024-9912"
|
||||
],
|
||||
"details": "A vulnerability was found in D-Link DIR-619L B1 2.06. It has been declared as critical. This vulnerability affects the function formSetQoS of the file /goform/formSetQoS. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
|
||||
},
|
||||
{
|
||||
"type": "CVSS_V4",
|
||||
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X"
|
||||
}
|
||||
],
|
||||
"affected": [
|
||||
|
||||
],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-9912"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/D-Link/DIR-619L/formSetQoS.md"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?ctiid.280240"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?id.280240"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?submit.418743"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.dlink.com"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-120"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2024-10-13T17:15:10Z"
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,58 @@
|
||||
{
|
||||
"schema_version": "1.4.0",
|
||||
"id": "GHSA-p3cw-2qg8-ghqq",
|
||||
"modified": "2024-10-13T18:30:46Z",
|
||||
"published": "2024-10-13T18:30:46Z",
|
||||
"aliases": [
|
||||
"CVE-2024-9914"
|
||||
],
|
||||
"details": "A vulnerability classified as critical has been found in D-Link DIR-619L B1 2.06. Affected is the function formSetWizardSelectMode of the file /goform/formSetWizardSelectMode. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.",
|
||||
"severity": [
|
||||
{
|
||||
"type": "CVSS_V3",
|
||||
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
|
||||
},
|
||||
{
|
||||
"type": "CVSS_V4",
|
||||
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X"
|
||||
}
|
||||
],
|
||||
"affected": [
|
||||
|
||||
],
|
||||
"references": [
|
||||
{
|
||||
"type": "ADVISORY",
|
||||
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-9914"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/D-Link/DIR-619L/formSetWizardSelectMode.md"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?ctiid.280242"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?id.280242"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://vuldb.com/?submit.418746"
|
||||
},
|
||||
{
|
||||
"type": "WEB",
|
||||
"url": "https://www.dlink.com"
|
||||
}
|
||||
],
|
||||
"database_specific": {
|
||||
"cwe_ids": [
|
||||
"CWE-120"
|
||||
],
|
||||
"severity": "HIGH",
|
||||
"github_reviewed": false,
|
||||
"github_reviewed_at": null,
|
||||
"nvd_published_at": "2024-10-13T18:15:03Z"
|
||||
}
|
||||
}
|
||||
Reference in New Issue