bingjingc aff69d89bd md/raid5: correct degraded calculation in raid5_error
When disk failure occurs on new disks for reshape, mddev->degraded
is not calculated correctly. Faulty bit of the failure device is not
set before raid5_calc_degraded(conf).

mdadm --create /dev/md0 --level=5 --raid-devices=3 /dev/loop[012]
mdadm /dev/md0 -a /dev/loop3
mdadm /dev/md0 --grow -n4
mdadm /dev/md0 -f /dev/loop3 # simulating disk failure

cat /sys/block/md0/md/degraded # it outputs 0, but it should be 1.

However, mdadm -D /dev/md0 will show that it is degraded. It's a bug.
It can be fixed by moving the resources raid5_calc_degraded() depends
on before it.

Reported-by: Roy Chung <roychung@synology.com>
Reviewed-by: Alex Wu <alexwu@synology.com>
Signed-off-by: BingJing Chang <bingjingc@synology.com>
Signed-off-by: Shaohua Li <shli@fb.com>
2017-12-01 11:27:32 -08:00
…
2017-11-29 09:27:35 -05:00
2017-11-26 16:01:47 -08:00

Linux kernel
============

This file was moved to Documentation/admin-guide/README.rst

Please notice that there are several guides for kernel developers and users.
These guides can be rendered in a number of formats, like HTML and PDF.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.
See Documentation/00-INDEX for a list of what is contained in each file.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Languages
C 97.8%
Assembly 1.5%
Makefile 0.3%
Shell 0.1%
Python 0.1%
Other 0.1%