hw/net/can: Remove redundant status bit setting in can_sja1000

In PeliCAN mode reception, the RBS (Receive Buffer Status) bit
is set twice at line 842 and 845 with identical operations:
  s->status_pel |= 0x01;
  s->status_pel |= (1 << 0);

Between these two operations, only interrupt_pel is modified and
status_pel bit 4 is cleared, neither affecting bit 0. The second
operation is redundant.

This cleanup aligns PeliCAN mode with BasicCAN mode, which correctly
sets this bit only once (line 883).

Signed-off-by: SillyZ <1357816113@qq.com>
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Michael Tokarev <mjt@tls.msk.ru>
Signed-off-by: Michael Tokarev <mjt@tls.msk.ru>
This commit is contained in:
SillyZ
2025-10-05 09:46:06 +03:00
committed by Michael Tokarev
parent c187a67c9d
commit d56a30a7bb
-1
View File
@@ -842,7 +842,6 @@ ssize_t can_sja_receive(CanBusClientState *client, const qemu_can_frame *frames,
s->status_pel |= 0x01; /* Set the Receive Buffer Status. DS-p23 */
s->interrupt_pel |= 0x01;
s->status_pel &= ~(1 << 4);
s->status_pel |= (1 << 0);
can_sja_update_pel_irq(s);
} else { /* BasicCAN mode */