stmp3xxx_wdt_register() can fail as platform_device_alloc() or
platform_device_add() can fail. But when it fails it failed silently.
Lets print out an error message on failure so that user will atlest
know that there was some error.
Signed-off-by: Sudip Mukherjee <sudip.mukherjee@codethink.co.uk>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
The IS_ENABLED() macro checks if a Kconfig symbol has been enabled either
built-in or as a module, use that macro instead of open coding the same.
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
The rtc->ops_lock would be accessed in ds3232_irq() without being
initialized as rtc_device_register() is called too late.
So move devm_rtc_device_register() just before registering irq handler
to initialize rtc->ops_lock earlier.
Signed-off-by: Gong Qianyu <Qianyu.Gong@nxp.com>
Reviewed-by: Akinobu Mita <akinobu.mita@gmail.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
If enable_irq_wake fails, we should return that error code so that
entering suspend fails. Otherwise we will get a WARNING along with
the hint of a unbalanced wake disable:
Unbalanced IRQ 37 wake disable
Signed-off-by: Stefan Agner <stefan@agner.ch>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
We program RTC time using SET_TIME_WRITE register and read the RTC
current time using CURRENT_TIME register. When we set the time by
writing into SET_TIME_WRITE Register and immediately try to read the
rtc time from CURRENT_TIME register, the previous old value is
returned instead of the new loaded time. This is because RTC takes
nearly 1 sec to update the new loaded value into the CURRENT_TIME
register. This behaviour is expected in our RTC IP.
This patch updates the driver to read the current time from SET_TIME_WRITE
register instead of CURRENT_TIME when rtc time is requested within an 1sec
period after setting the RTC time. Doing so will ensure the correct time is
given to the user.
Since there is a delay of 1sec in updating the CURRENT_TIME we are loading
set time +1sec while programming the SET_TIME_WRITE register, doing this
will give correct time without any delay when read from CURRENT_TIME.
Signed-off-by: Anurag Kumar Vulisha <anuragku@xilinx.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
The RTC core handles it since 6610e08 (RTC: Rework RTC code to use
timerqueue for events). So far, only the callbacks to the RTC core have
been removed, but not the handlers. Do this now.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
It is suggested to program CALIB_WRITE register with the calibration
value before updating the SET_TIME_WRITE register, doing so will
clear the Tick Counter and force the next second to be signaled
exactly in 1 second.
Signed-off-by: Anurag Kumar Vulisha <anuragku@xilinx.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
In order to conserve battery energy, during the PS operation,
it is expected that the supply for the battery-powered domain
to be switched from the battery (VCC_PSBATT) to (VCC_PSAUX) and
automatically be switched back to battery when VCC_PSAUX voltage
drops below a limit, doing so prevents the logic within
the battery-powered domain from functioning incorrectly.
Signed-off-by: Anurag Kumar Vulisha <anuragku@xilinx.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
objtool reports the following warning:
drivers/rtc/rtc-ds1685.o: warning: objtool: ds1685_rtc_poweroff() falls through to next function ds1685_rtc_work_queue()
Similar to commit 361c6ed6b1 ("rtc: ds1685: actually spin forever in
poweroff error path"), there's another unreachable() annotation which is
actually reachable, which we missed the first time.
Actually spin forever to be consistent with the comment and to make the
unreachable() annotation guaranteed to be unreachable.
Reported-by: kbuild test robot <fengguang.wu@intel.com>
Signed-off-by: Josh Poimboeuf <jpoimboe@redhat.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
This fix alters the ordering of the IRQ and device registrations in the RTC
driver probe function. This change will apply to the RTC driver that supports
both DA9052 and DA9053 PMICs.
A problem could occur with the existing RTC driver if:
A system is started from a cold boot using the PMIC RTC IRQ to initiate a
power on operation. For instance, if an RTC alarm is used to start a
platform from power off.
The existing driver IRQ is requested before the device has been properly
registered.
i.e.
ret = da9052_request_irq()
comes before
rtc->rtc = devm_rtc_device_register();
In this case, an interrupt exists before the device has been registered and
the IRQ handler can be called immediately: this can happen be before the
memory for rtc->rtc has been allocated. The IRQ handler da9052_rtc_irq()
contains the function call:
rtc_update_irq(rtc->rtc, 1, RTC_IRQF | RTC_AF);
which in turn tries to access the unavailable rtc->rtc.
The fix is to reorder the functions inside the RTC probe. The IRQ is
requested after the RTC device resource has been registered so that
da9052_request_irq() is the last thing to happen.
Signed-off-by: Steve Twiss <stwiss.opensource@diasemi.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
If a previously-set alarm was disabled and then triggered, it may still
be pending when a new alarm is configured.
Then, if the alarm is enabled before the pending alarm is cleared, then
an interrupt is immediately raised.
Unfortunately, when the alarm is cleared and enabled during the same I²C
block write, the chip (at least the DS1339 I have) considers that the
alarm is enabled before it is cleared, and raises an interrupt.
This patch ensures that the pending alarm is cleared before the alarm is
enabled.
Signed-off-by: Nicolas Boullis <nboullis@debian.org>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
The i2c_smbus_read_i2c_block_data function returns 0 on success, not the
number of bytes written.
Hence, when there are 32 bytes or less to send, the
ds1307_native_smbus_write_block_data function returns 0 on success,
while it returns the number of bytes when there are more than 32.
The ds1307_write_block_data always returns the number of bytes on
success.
Signed-off-by: Nicolas Boullis <nboullis@debian.org>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Handle the Oscillator Failure (OF) bit on each read of date-time.
If the OF is set, an error is returned (-EINVAL) instead of the date-time.
The OF bit is cleared each time the date is set.
Signed-off-by: Mylène Josserand <mylene.josserand@free-electrons.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
To enable the wakealarm, the device must be able to wakeup.
This is done by setting the device wakeup capability to true with
'device_init_wakeup' function.
Signed-off-by: Mylène Josserand <mylene.josserand@free-electrons.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Previous 'commit c3b79770e5 ("Expire alarms after the time is set")'
and 'commit 48e9766726 ("remove disabled alarm functionality")' removed
the alarm support because the alarm irq was not functional.
Add the alarm IRQ functionality with newer functions than previous
code. Tested with 'rtctest' and the alarm is functional.
Signed-off-by: Mylène Josserand <mylene.josserand@free-electrons.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>