Currently fc_disc_timeout() restarts discovery only if it is not pending.
When the timer is scheduled, the discovery is left pending, so the
timeout never restarts it.
Fix by not checking for pending in the timeout handler.
If discovery is stopped and restarted in the meantime, the timeout will
be canceled.
Also, when a new discovery is started, the retry count wasn't cleared.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
On some switches, an empty zone causes GPN_FT to be rejected
with reason 9 (unable) explanation 7 (FC-4 types not registered),
which causes discovery to be retried endlessly. Treat this as
just an empty response and consider discovery complete.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Abhijeet Joglekar wrote: "In gpn_ft_resp, if the payload is short,
or unexpected response or out of sequence frame, then we just
return and do nothing. We should either enter fc_disc_done()
with DISC_EV_FAIL which will then restart any queued discovery
requests or call lport module which will reset local port,
or we should call fc_disc_error() so that the gpn_ft is retried.
The situation as is causes discovery to remain pending and never
get restarted, in these rare cases. We saw this due to a coding
bug in fc_disc before. The only ways it could happen would be
bugs, packet corruption or an FC fabric problem.
Change it to fail discovery. The local port will restart
discovery, although it probably should just give up until
the next link flap.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Code cleanup for fc_disc_gpn_ft_resp().
Some of the fc_disc.c code was poorly formatted. For example, some lines
in fc_disc.c were unnecessarily truncated and the buf variable could
be eliminated.
Also moved the increment of seq_count into fc_disc_gpn_ft_parse(), to
avoid doing it separately before each call.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When an RSCN is received during fabric discovery, it restarts.
After the restart, disc->seq_count was incremented, so when
the first frame was received, it was considered "out of sequence".
That left the state disc->active, preventing further discoveries.
Change to advance the sequence count before parsing, so that it
won't be changed after a potential restart.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When receiving an RSCN, do not log off all rports. This is
extremely disruptive. If, after the GPN_FT response, some
rports haven't been listed, delete them.
Add field disc_id to structs fc_rport_priv and fc_disc.
disc_id is an arbitrary serial number used to identify the
rports found by the latest discovery. This eliminates the need
to go through the rport list when restarting discovery.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Move the libfc remote port lookup function into fc_rport.c.
This seems like the best place for it.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Since the rport list maintenance is now done in the rport module,
the callback (and ops) are usually not necessary.
Allow rdata->ops to be left NULL if nothing needs
to be done in an event callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For future discovery patches, change rport_create to return a previously
created rport_priv that has the FC_ID as long as it isn't in deleted state.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The list of remote ports (struct fc_rport_priv) has been
maintained by the discovery module. In preparation for having
lport->tt.rport_create() do a lookup first, maintain the
rports list in the rport module. It will still be protected
by the disc_mutex.
The DNS rport is an exception for until after further patches.
For now, do not add it to the list.
The point-to-point rport will be in the discovery list.
So at shutdown, it doesn't need to be separately logged out.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The lport rport callback can only be called for the dNS rport,
since its the only rport who's ops point to that function.
Remove unnecessary checking and debug messages.
Put the locking outside the switch statement as a simplification.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't print large negative decimal numbers for frame pointers in
the debug messages from fc_rport_error(). Just print 0 if its a
frame pointer, and print the error numbers as positive.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
There was no need to have the discovery status stored in struct fc_disc.
Change fc_disc_done() to take the discovery status as an argument
and just pass it on to the discovery callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When a remote port becomes ready and a LOGO is received before
the READY event is in rport_work waiting on the mutex, the
event is changed to LOGO and the work queued, so both the
calls to rport_work see the LOGO event, and both try to do
the list_del(), causing a crash.
Don't change the event if it is already set.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't create a "dummy" remote port to go with fc_rport_priv.
Make the rport truly optional by allocating fc_rport_priv separately
and not requiring a dummy rport to be there if we haven't yet done
fc_remote_port_add().
The fc_rport_libfc_priv remains as a structure attached to the
rport for I/O purposes.
Be sure to hold references on rdata when the lock is dropped in
fc_rport_work().
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Remote ports will become READY more than once after
ADISC is implemented in a later patch.
The event callback that has been called "CREATED" will mean "READY".
Rename it now in preparation for those changes.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This is a cleanup without semantic changes to use a switch
statement instead of a series of if-statements in fc_rport_work(),
and to move some declarations up to the top.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Allow a struct fc_rport_priv to have no fc_rport associated with it.
This sets up to remove the need for "rogue" rports.
Add a few fields to fc_rport_priv that are needed before the fc_rport
is created. These are the ids, maxframe_size, classes, and rport pointer.
Remove the macro PRIV_TO_RPORT(). Just use rdata->rport where appropriate.
To take the place of the get_device()/put_device ops that were used to
hold both the rport and rdata, add a reference count to rdata structures
using kref. When kref_get decrements the refcount to zero, a new template
function releasing the rdata should be called. This will take care of
freeing the rdata and releasing the hold on the rport (for now). After
subsequent patches make the rport truly optional, this release function
will simply free the rdata.
Remove the simple inline function fc_rport_set_name(), which becomes
semanticly ambiguous otherwise. The caller will set the port_name and
node_name in the rdata->Ids, which will later be copied to the rport
when it its created.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
tt.elsct_send is used by both FCP and by the rport state machine.
After further patches, these two modules will use different
structures for the remote port.
So, change elsct_send to use the FC_ID instead of the fc_rport_priv
as its argument. It currently only uses the FC_ID anyway.
For CT requests the destination FC_ID is still implicitly 0xfffffc.
After further patches the did arg on CT requests will be used to
specify the FC_ID being inquired about for GPN_ID or other queries.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The rport and discovery modules deal with remote ports
before fc_remote_port_add() can be done, because the
full set of rport identifiers is not known at early stages.
In preparation for splitting the fc_rport/fc_rport_priv allocation,
make fc_rport_priv the primary interface for the remote port and
discovery engines.
The FCP / SCSI layers still deal with fc_rport and
fc_rport_libfc_priv, however.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
These macros introduce extra undesirable semicolons that keep
them from being used in expressions, and they don't protect
against being passed an expression.
Add parens and remove the semicolons.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The interface for lport->tt.rport_create() takes a fc_disc_port arg,
which is unnatural for most calls. The only reason for this was
to avoid passing in the local port as an argument, but otherwise
added to complexity.
Simplify by just using lport and fc_rport_identifiers.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
While the I/O and LLD interfaces use fc_rport_libfc_priv, the
disc and rport interfaces will use fc_rport_priv, which will
be separately allocated.
Change the disc and rport usage of fc_rport_libfc_priv to fc_rport_priv.
Use #define temporarily to make both names equivalent until a
subsequent patch splits them.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This just cuts down on the number of locks we're dealing with, and
eliminates the need to take another lock in the netdev notifier.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>