If .is_enabled callback is not implemented, regulator core assumes that the
regulator is always on. Thus we don't need mc13xxx_sw_regulator_is_enabled
function.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Due to the lack of a generic clock API we'd had the 32kHz clock in the
regulator driver but this is definitely a Linux-specific thing and now
we have a clock API hopefully the code can be moved elsewhere. Try to
avoid getting DTs deployed relying on the 32kHz clock by removing it
from the bindings, grep seems to tell me it's not currently used anyway.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For table based mapping, we can calculate voltage difference by below equation:
abs(rdev->desc->volt_table[new_selector] - rdev->desc->volt_table[old_selector])
Thus we can make regulator_set_voltage_time_sel work for table based mapping.
regulator_set_voltage_time_sel() only supports linear or table based mapping.
In case it is misused, also warn if neither linear nor table based mapping
is used with regulator_set_voltage_time_sel().
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For some hardwares ramp_delay for BUCKs is a configurable parameter which can
be configured through DT or board file.This patch adds ramp_delay to regulator
constraints and allow user to configure it for regulators which supports this
feature, through DT or board file. It will provide two ways of setting the
ramp_delay for a regulator:
First, by setting it as constraints in board file(for configurable
regulators) and set_machine_constraints() will take care of setting it on
hardware by calling(the provided) .set_ramp_delay() operation(callback).
Second, by setting it as data in regulator_desc(as fixed/default
ramp_delay rate) for a regulator in driver.
regulator_set_voltage_time_sel() will give preference to
constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly
users should also take care accordingly while refering ramp_delay rate(in case
of implementing their private .set_voltage_time_sel() callbacks for different
regulators).
[Rewrote subject for 80 columns -- broonie]
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The min_uV and max_uV are not really used in the code and misleading because
the min_uV and max_uV settings does not match the value in the voltage table.
For example, we have
static const unsigned int ldo_vaux3_voltages[] = {
1200000,
1500000,
1800000,
2100000,
2500000,
2750000,
2790000,
2910000,
};
With below min_uV/max_uV settings for AB8500_LDO_AUX3.
.min_uV = 1100000,
.max_uV = 3300000,
The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2
and is wrong.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops
because the voltage won't change. ( And ab8500_regulator_fixed_ops does not
implement get_voltage_sel so set_voltage_time_sel won't be called )
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0]
falls with min_uV and max_uV.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For linear mappings, we can use below equation to get the voltage difference
between new_selector and old_selector:
abs(new_selector - old_selector) * rdev->desc->uV_step
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Reuse map_voltage() to get the selector of a given uV.
Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val().
Also remove unused wm8350_dcdc_val_to_mvolts() function.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage
falls within specified range.
Use wm8350_ldo_list_voltage() here is less error prone.
wm8350_ldo_val_to_mvolts() is only used in wm8350_ldo_list_voltage now, so
remove it and move the implementation to wm8350_ldo_list_voltage().
This patch also include below small changes in wm8350_ldo_map_voltage:
1. wm8350_ldo_map_voltage() returns selector, thus rename variable mV to sel.
2. Use DIV_ROUND_UP macro to calculate selector.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch converts .is_enabled and .get_voltage_sel to
regulator_is_enabled_regmap and regulator_get_voltage_sel_regmap.
For .enable, .disable, and .set_voltage_sel, the write protect level is either
1 or 2. So we cannot use regulator_[enable|disable|set_voltage_sel]_regmap.
Now we store the enable reg/mask and vsel reg/mask in regulator_desc,
so we can remove enable_mask, set_vout_reg, and set_vout_mask from
struct tps_info.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Adjust the equation for selector >= 15 for better readability.
The equation "1700000 + ((selector - 15) * 100000)" can be interpreted by:
Starting from selector 15: Steps of 100mV from 1700mV
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Call wm8400_ldo_list_voltage() instead of open code to verify selected voltage
falls within specified range.
Use wm8400_ldo_list_voltage() here is less error prone.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>