Atmel ISI support a preview path which can output RGB data.
So this patch introduces a bool variable to choose which path is
enabled currently. And also we need setup corresponding path registers.
By default the preview path is disabled. We only use Codec path.
Signed-off-by: Josh Wu <josh.wu@atmel.com>
Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
we need to configure the YCC_SWAP bits in ISI_CFG2 according to current
sensor output and Atmel ISI output format.
Current there are two cases Atmel ISI supported:
1. Atmel ISI outputs YUYV format.
This case we need to setup YCC_SWAP according to sensor output
format.
2. Atmel ISI output a pass-through formats, which means no swap.
Just setup YCC_SWAP as default with no swap.
Signed-off-by: Josh Wu <josh.wu@atmel.com>
Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
The soc-camera host will be probed and register a v4l2_clk, but if at
that moment, the i2c device is not available, then the registered
v4l2_clk name is an OF string not a I2C string.
So when i2c sensor probes and calls v4l2_clk_get(), it only searches a
clock with I2C string, like "1-0030".
This patch will search the clock with OF string name if no clock with
I2C string name could be found.
Signed-off-by: Josh Wu <josh.wu@atmel.com>
Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Make all v4l2-clk's clock name use V4L2_CLK_NAME_SIZE definition.
In future, if the string is increased we just need to change the
V4L2_CLK_NAME_SIZE once.
Signed-off-by: Josh Wu <josh.wu@atmel.com>
Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
With this patch, vivid capture thread can now generate a video with
frame rate reduced by a factor of 1000 / 1001. This option can be
selected using a control Reduced Framerate from gui.
Signed-off-by: Prashant Laddha <prladdha@cisco.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
A boolean control Reduced Framerate is added to vivid controls for
controlling the reduced fps option for vivid capture from gui.
Signed-off-by: Prashant Laddha <prladdha@cisco.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
If reduced fps flag is set then check if other necessary conditions
are true for the given bt timing. If yes, then reduce the frame rate.
For vivid transmitter, timeperframe_vid_out controls the frame rate.
Adjusting the timeperframe_vid_out by scaling down pixel clock by
factor of 1000 / 1001.
Signed-off-by: Prashant Laddha <prladdha@cisco.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Added a helper function to check necessary conditions required for
reduced fps. The reduced fps is supported for CVT and CEA861 timings.
CVT supports reduced fps only if reduced blanking v2 (indicated by
vsync = 8) is true. Whereas CEA861 supports reduced fps if
V4L2_DV_FL_CAN_REDUCE_FPS flag is true.
Signed-off-by: Prashant Laddha <prladdha@cisco.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
When a V4L2 sub-device backed by a DT or ACPI based device was removed,
the device was unregistered as well which certainly was not intentional,
as the client device would not be re-created by simply reinstating the
V4L2 sub-device (indeed the device would have to be there first!).
Skip unregistering the device in case it has non-NULL of_node or fwnode.
Signed-off-by: Tommi Franttila <tommi.franttila@intel.com>
Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Initialization of the ADV7180 chip fails on the Renesas R8A7790-based
Lager board about 50% of the time. This patch resolves the issue by
increasing the minimum delay after reset from 2 ms to 5 ms, following the
recommendation in the ADV7180 datasheet:
"Executing a software reset takes approximately 2 ms. However, it is
recommended to wait 5 ms before any further I2C writes are performed."
Signed-off-by: Ulrich Hecht <ulrich.hecht+renesas@gmail.com>
Acked-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Acked-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
The sh-vou driver has been converted from videobuf to videobuf2, but
the Kconfig file still lists VIDEOBUF_DMA_CONTIG as a dependency.
Consequently we can build the driver without VIDEOBUF2_DMA_CONTIG
and get a link error:
drivers/built-in.o: In function `sh_vou_probe':
vf610-ocotp.c:(.text+0x2dbf5c): undefined reference to `vb2_dma_contig_init_ctx'
vf610-ocotp.c:(.text+0x2dc0b4): undefined reference to `vb2_dma_contig_cleanup_ctx'
vf610-ocotp.c:(.text+0x2dc144): undefined reference to `vb2_dma_contig_memops'
drivers/built-in.o: In function `sh_vou_remove':
vf610-ocotp.c:(.text+0x2dc190): undefined reference to `vb2_dma_contig_cleanup_ctx'
This changes the dependency to VIDEOBUF2_DMA_CONTIG instead.
Fixes: 57af3ad59d ("[media] sh-vou: convert to vb2")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
cpia2_usb_disconnect() seems to be missing a memory barrier which might
cause the waker to not notice the waiter and miss sending a wake_up as
in the following figure.
cpia2_usb_disconnect sync
------------------------------------------------------------------------
mutex_unlock(&cam->v4l2_lock);
if (waitqueue_active(&cam->wq_stream))
/* The CPU might reorder the test for
the waitqueue up here, before
prior writes complete */
/* wait_event_interruptible */
/* __wait_event_interruptible */
/* ___wait_event */
long __int = prepare_to_wait_event(
&wq, &__wait, state);
if (!cam->streaming ||
frame->status == FRAME_READY)
cam->curbuff->status = FRAME_READY;
cam->curbuff->length = 0;
schedule()
------------------------------------------------------------------------
The attached patch removes the call to waitqueue_active() leaving just
wake_up() behind. This fixes the problem because the call to
spin_lock_irqsave() in wake_up() will be an ACQUIRE operation.
I found this issue when I was looking through the linux source code
for places calling waitqueue_active() before wake_up*(), but without
preceding memory barriers, after sending a patch to fix a similar
issue in drivers/tty/n_tty.c (Details about the original issue can be
found here: https://lkml.org/lkml/2015/9/28/849).
Signed-off-by: Kosuke Tatsukawa <tatsu@ab.jp.nec.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
The current cx231xx driver doesn't work with bulk transfer mode.
This patch makes it possible to use bulk transfer mode.
Signed-off-by: Terry Heo <terryheo@google.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
The radio_tea5777_ops structure is never modified, so declare it as const.
Done with the help of Coccinelle.
Signed-off-by: Julia Lawall <Julia.Lawall@lip6.fr>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
This driver does not use the control infrastructure.
Add support for the new field which on structure
v4l2_ext_controls
Acked-by: Mike Isely <isely@pobox.com>
Signed-off-by: Ricardo Ribalda Delgado <ricardo.ribalda@gmail.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Support for new field which on v4l2_ext_controls, used to get the
default value of one or more controls.
Signed-off-by: Ricardo Ribalda Delgado <ricardo.ribalda@gmail.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Replace the obsolete field ctrl_class with "which".
Make sure it not used in future modules by commenting out the field with
ifndef __KERNEL_ .
The field cannot be simply removed because that would be change on the
kenel API to the userspace (and we don't like that).
Signed-off-by: Ricardo Ribalda Delgado <ricardo.ribalda@gmail.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
So it can be used to get the default value of a control.
Without this change it is not possible to get the
default value of array controls.
Signed-off-by: Ricardo Ribalda Delgado <ricardo.ribalda@gmail.com>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>