Jo Shields a575963da9 Imported Upstream version 3.6.0
Former-commit-id: da6be194a6b1221998fc28233f2503bd61dd9d14
2014-08-13 10:39:27 +01:00

153 lines
8.7 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Type Name="ConnectionManagementElement" FullName="System.Net.Configuration.ConnectionManagementElement">
<TypeSignature Language="C#" Value="public sealed class ConnectionManagementElement : System.Configuration.ConfigurationElement" />
<TypeSignature Language="ILAsm" Value=".class public auto ansi sealed ConnectionManagementElement extends System.Configuration.ConfigurationElement" />
<AssemblyInfo>
<AssemblyName>System</AssemblyName>
<AssemblyVersion>2.0.0.0</AssemblyVersion>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<Base>
<BaseTypeName>System.Configuration.ConfigurationElement</BaseTypeName>
</Base>
<Interfaces />
<Docs>
<since version=".NET 2.0" />
<remarks>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>This class corresponds to the <format type="text/html"><a href="856bf57d-1c63-46c7-a178-03d97b0a4149">Add Element for ConnectionManagement (Network Settings)</a></format> configuration element.</para>
<para>This class is used to specify the maximum number of simultaneous connections to a remote computer. </para>
<para>This class provides programmatic access to information that can be stored in configuration files.</para>
</remarks>
<summary>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>Represents the maximum number of connections to a remote computer. This class cannot be inherited.</para>
</summary>
</Docs>
<Members>
<Member MemberName=".ctor">
<MemberSignature Language="C#" Value="public ConnectionManagementElement ();" />
<MemberSignature Language="ILAsm" Value=".method public hidebysig specialname rtspecialname instance void .ctor() cil managed" />
<MemberType>Constructor</MemberType>
<AssemblyInfo>
<AssemblyVersion>2.0.0.0</AssemblyVersion>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<Parameters />
<Docs>
<remarks>To be added.</remarks>
<since version=".NET 2.0" />
<summary>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>Initializes a new instance of the <see cref="T:System.Net.Configuration.ConnectionManagementElement" /> class. </para>
</summary>
</Docs>
</Member>
<Member MemberName=".ctor">
<MemberSignature Language="C#" Value="public ConnectionManagementElement (string address, int maxConnection);" />
<MemberSignature Language="ILAsm" Value=".method public hidebysig specialname rtspecialname instance void .ctor(string address, int32 maxConnection) cil managed" />
<MemberType>Constructor</MemberType>
<AssemblyInfo>
<AssemblyVersion>2.0.0.0</AssemblyVersion>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<Parameters>
<Parameter Name="address" Type="System.String" />
<Parameter Name="maxConnection" Type="System.Int32" />
</Parameters>
<Docs>
<since version=".NET 2.0" />
<remarks>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>This constructor sets the <see cref="P:System.Net.Configuration.ConnectionManagementElement.Address" /> property to <paramref name="address" /> and the <see cref="P:System.Net.Configuration.ConnectionManagementElement.MaxConnection" /> property to <paramref name="maxConnection" />.</para>
</remarks>
<summary>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>Initializes a new instance of the <see cref="T:System.Net.Configuration.ConnectionManagementElement" /> class with the specified address and connection limit information.</para>
</summary>
<param name="address">
<attribution license="cc4" from="Microsoft" modified="false" />A string that identifies the address of a remote computer.</param>
<param name="maxConnection">
<attribution license="cc4" from="Microsoft" modified="false" />An integer that identifies the maximum number of connections allowed to <paramref name="address" /> from the local computer.</param>
</Docs>
</Member>
<Member MemberName="Address">
<MemberSignature Language="C#" Value="public string Address { get; set; }" />
<MemberSignature Language="ILAsm" Value=".property instance string Address" />
<MemberType>Property</MemberType>
<AssemblyInfo>
<AssemblyVersion>2.0.0.0</AssemblyVersion>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<Attributes>
<Attribute>
<AttributeName>System.Configuration.ConfigurationProperty("address", Options=System.Configuration.ConfigurationPropertyOptions.IsRequired | System.Configuration.ConfigurationPropertyOptions.IsKey)</AttributeName>
</Attribute>
</Attributes>
<ReturnValue>
<ReturnType>System.String</ReturnType>
</ReturnValue>
<Docs>
<value>To be added.</value>
<since version=".NET 2.0" />
<remarks>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>You can set this property using an asterisk (*) to set the default number of connections for unspecified computers.</para>
<para>This property identifies one or more remote computers and the <see cref="P:System.Net.Configuration.ConnectionManagementElement.MaxConnection" /> property specifies how many simultaneous connections are allowed between the local computer and the remote computers. </para>
</remarks>
<summary>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>Gets or sets the address for remote computers.</para>
</summary>
</Docs>
</Member>
<Member MemberName="MaxConnection">
<MemberSignature Language="C#" Value="public int MaxConnection { get; set; }" />
<MemberSignature Language="ILAsm" Value=".property instance int32 MaxConnection" />
<MemberType>Property</MemberType>
<AssemblyInfo>
<AssemblyVersion>2.0.0.0</AssemblyVersion>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<Attributes>
<Attribute>
<AttributeName>System.Configuration.ConfigurationProperty("maxconnection", DefaultValue=Mono.Cecil.CustomAttributeArgument, Options=System.Configuration.ConfigurationPropertyOptions.IsRequired)</AttributeName>
</Attribute>
</Attributes>
<ReturnValue>
<ReturnType>System.Int32</ReturnType>
</ReturnValue>
<Docs>
<value>To be added.</value>
<since version=".NET 2.0" />
<remarks>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>This property specifies how many simultaneous connections are allowed between the local computer and the remote computer. The remote computer is specified using the <see cref="P:System.Net.Configuration.ConnectionManagementElement.Address" /> property.</para>
<para>The <see cref="P:System.Net.Configuration.ConnectionManagementElement.MaxConnection" /> property is per <see cref="P:System.Net.WebRequest.ConnectionGroupName" />. If an application is not changing <see cref="P:System.Net.WebRequest.ConnectionGroupName" /> from the default, then the <see cref="P:System.Net.Configuration.ConnectionManagementElement.MaxConnection" /> property applies to the entire application domain. If only a single application domain is running in your application, then the <see cref="P:System.Net.Configuration.ConnectionManagementElement.MaxConnection" /> property setting is application-wide. </para>
</remarks>
<summary>
<attribution license="cc4" from="Microsoft" modified="false" />
<para>Gets or sets the maximum number of connections that can be made to a remote computer.</para>
</summary>
</Docs>
</Member>
<Member MemberName="Properties">
<MemberSignature Language="C#" Value="protected override System.Configuration.ConfigurationPropertyCollection Properties { get; }" />
<MemberSignature Language="ILAsm" Value=".property instance class System.Configuration.ConfigurationPropertyCollection Properties" />
<MemberType>Property</MemberType>
<AssemblyInfo>
<AssemblyVersion>2.0.0.0</AssemblyVersion>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Configuration.ConfigurationPropertyCollection</ReturnType>
</ReturnValue>
<Docs>
<summary>To be added.</summary>
<value>To be added.</value>
<remarks>To be added.</remarks>
<since version=".NET 2.0" />
</Docs>
</Member>
</Members>
</Type>