184 lines
12 KiB
XML
184 lines
12 KiB
XML
|
<?xml version="1.0" encoding="utf-8"?>
|
||
|
<Type Name="SourceSwitch" FullName="System.Diagnostics.SourceSwitch">
|
||
|
<TypeSignature Language="C#" Value="public class SourceSwitch : System.Diagnostics.Switch" />
|
||
|
<TypeSignature Language="ILAsm" Value=".class public auto ansi beforefieldinit SourceSwitch extends System.Diagnostics.Switch" />
|
||
|
<AssemblyInfo>
|
||
|
<AssemblyName>System</AssemblyName>
|
||
|
<AssemblyVersion>2.0.0.0</AssemblyVersion>
|
||
|
<AssemblyVersion>4.0.0.0</AssemblyVersion>
|
||
|
</AssemblyInfo>
|
||
|
<Base>
|
||
|
<BaseTypeName>System.Diagnostics.Switch</BaseTypeName>
|
||
|
</Base>
|
||
|
<Interfaces />
|
||
|
<Docs>
|
||
|
<remarks>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>The <see cref="P:System.Diagnostics.TraceSource.Switch" /> property of the <see cref="T:System.Diagnostics.TraceSource" /> class is a <see cref="T:System.Diagnostics.SourceSwitch" /> object. The <see cref="T:System.Diagnostics.SourceSwitch" /> class provides a <see cref="P:System.Diagnostics.SourceSwitch.Level" /> property to test the event level of the switch. The <see cref="P:System.Diagnostics.SourceSwitch.Level" /> property gets or sets the switch's <see cref="T:System.Diagnostics.TraceLevel" /> value.</para>
|
||
|
<para>You can set the event level of a <see cref="T:System.Diagnostics.SourceSwitch" /> through the application configuration file and then use the configured <see cref="T:System.Diagnostics.SourceSwitch" /> level in your application. Alternatively, you can create a <see cref="T:System.Diagnostics.SourceSwitch" /> in your code and set the level directly, to instrument a specific section of code.</para>
|
||
|
<para>To configure a <see cref="T:System.Diagnostics.SourceSwitch" />, edit the configuration file that corresponds to the name of your application. Within this file, you can set a switch's value or clear all the switches previously set by the application. The configuration file should be formatted as shown in the following example. </para>
|
||
|
<code><switches>
|
||
|
<add name="SourceSwitch" value="Verbose"></add>
|
||
|
</switches></code>
|
||
|
<para>The switch is used to check whether a trace should be propagated or ignored. Each <see cref="T:System.Diagnostics.TraceSource" /> trace method calls the <see cref="M:System.Diagnostics.SourceSwitch.ShouldTrace(System.Diagnostics.TraceEventType)" /> method before calling the listeners. If the <see cref="M:System.Diagnostics.SourceSwitch.ShouldTrace(System.Diagnostics.TraceEventType)" /> method returns false, the trace is ignored and the trace method exits. If the <see cref="M:System.Diagnostics.SourceSwitch.ShouldTrace(System.Diagnostics.TraceEventType)" /> method returns true, the trace is passed to the listeners.</para>
|
||
|
</remarks>
|
||
|
<summary>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>Provides a multilevel switch to control tracing and debug output without recompiling your code.</para>
|
||
|
</summary>
|
||
|
</Docs>
|
||
|
<Members>
|
||
|
<Member MemberName=".ctor">
|
||
|
<MemberSignature Language="C#" Value="public SourceSwitch (string displayName);" />
|
||
|
<MemberSignature Language="ILAsm" Value=".method public hidebysig specialname rtspecialname instance void .ctor(string displayName) cil managed" />
|
||
|
<MemberType>Constructor</MemberType>
|
||
|
<AssemblyInfo>
|
||
|
<AssemblyVersion>2.0.0.0</AssemblyVersion>
|
||
|
<AssemblyVersion>4.0.0.0</AssemblyVersion>
|
||
|
</AssemblyInfo>
|
||
|
<Parameters>
|
||
|
<Parameter Name="displayName" Type="System.String" />
|
||
|
</Parameters>
|
||
|
<Docs>
|
||
|
<param name="displayName">To be added.</param>
|
||
|
<remarks>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>The <paramref name="name" /> parameter is used to set the value of the <see cref="P:System.Diagnostics.Switch.DisplayName" /> property.</para>
|
||
|
<para>To set the level of your <see cref="T:System.Diagnostics.SourceSwitch" />, edit the configuration file that corresponds to the name of your application. Within this file, you can add a switch and set its value, remove a switch, or clear all the switches previously set by the application. To add a source switch, the configuration file should be formatted as shown in the following example. </para>
|
||
|
<code><configuration>
|
||
|
<system.diagnostics>
|
||
|
<switches>
|
||
|
<add name="SourceSwitch" value="Verbose" ></add>
|
||
|
</switches>
|
||
|
</system.diagnostics>
|
||
|
</configuration></code>
|
||
|
</remarks>
|
||
|
<summary>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>Initializes a new instance of the <see cref="T:System.Diagnostics.SourceSwitch" /> class, specifying the name of the source.</para>
|
||
|
</summary>
|
||
|
</Docs>
|
||
|
</Member>
|
||
|
<Member MemberName=".ctor">
|
||
|
<MemberSignature Language="C#" Value="public SourceSwitch (string displayName, string defaultSwitchValue);" />
|
||
|
<MemberSignature Language="ILAsm" Value=".method public hidebysig specialname rtspecialname instance void .ctor(string displayName, string defaultSwitchValue) cil managed" />
|
||
|
<MemberType>Constructor</MemberType>
|
||
|
<AssemblyInfo>
|
||
|
<AssemblyVersion>2.0.0.0</AssemblyVersion>
|
||
|
<AssemblyVersion>4.0.0.0</AssemblyVersion>
|
||
|
</AssemblyInfo>
|
||
|
<Parameters>
|
||
|
<Parameter Name="displayName" Type="System.String" />
|
||
|
<Parameter Name="defaultSwitchValue" Type="System.String" />
|
||
|
</Parameters>
|
||
|
<Docs>
|
||
|
<remarks>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>The <paramref name="displayName" /> parameter is used to set the value of the <see cref="P:System.Diagnostics.Switch.DisplayName" /> property; the <paramref name="defaultSwitchValue" /> parameter is saved as a field and used to initialize the <see cref="P:System.Diagnostics.Switch.Value" /> property on first reference. </para>
|
||
|
<block subset="none" type="note">
|
||
|
<para>If the switch is defined in a configuration file and the value attribute is specified, the configuration file value takes precedence and the <paramref name="defaultSwitchValue" /> is ignored.</para>
|
||
|
</block>
|
||
|
<para>To set the level of your <see cref="T:System.Diagnostics.SourceSwitch" />, edit the configuration file that corresponds to the name of your application. Within this file, you can add a switch and set its value, remove a switch, or clear all the switches previously set by the application. To add a source switch, the configuration file should be formatted as shown in the following example. </para>
|
||
|
<code><configuration>
|
||
|
<system.diagnostics>
|
||
|
<switches>
|
||
|
<add name="SourceSwitch" value="Verbose" ></add>
|
||
|
</switches>
|
||
|
</system.diagnostics>
|
||
|
</configuration></code>
|
||
|
</remarks>
|
||
|
<summary>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>Initializes a new instance of the <see cref="T:System.Diagnostics.SourceSwitch" /> class, specifying the display name and the default value for the source switch.</para>
|
||
|
</summary>
|
||
|
<param name="displayName">
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />The name of the source switch. </param>
|
||
|
<param name="defaultSwitchValue">
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />The default value for the switch. </param>
|
||
|
</Docs>
|
||
|
</Member>
|
||
|
<Member MemberName="Level">
|
||
|
<MemberSignature Language="C#" Value="public System.Diagnostics.SourceLevels Level { get; set; }" />
|
||
|
<MemberSignature Language="ILAsm" Value=".property instance valuetype System.Diagnostics.SourceLevels Level" />
|
||
|
<MemberType>Property</MemberType>
|
||
|
<AssemblyInfo>
|
||
|
<AssemblyVersion>2.0.0.0</AssemblyVersion>
|
||
|
<AssemblyVersion>4.0.0.0</AssemblyVersion>
|
||
|
</AssemblyInfo>
|
||
|
<ReturnValue>
|
||
|
<ReturnType>System.Diagnostics.SourceLevels</ReturnType>
|
||
|
</ReturnValue>
|
||
|
<Docs>
|
||
|
<value>To be added.</value>
|
||
|
<remarks>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>This property gets its value from the <see cref="P:System.Diagnostics.Switch.SwitchSetting" /> property. Setting this property also modifies the <see cref="P:System.Diagnostics.Switch.SwitchSetting" /> property. </para>
|
||
|
<block subset="none" type="note">
|
||
|
<para>For extensibility, the <see cref="P:System.Diagnostics.SourceSwitch.Level" /> property can be set to any integer, rather than being limited to a <see cref="T:System.Diagnostics.SourceLevels" /> enumeration value. </para>
|
||
|
</block>
|
||
|
</remarks>
|
||
|
<summary>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>Gets or sets the level of the switch.</para>
|
||
|
</summary>
|
||
|
</Docs>
|
||
|
</Member>
|
||
|
<Member MemberName="OnValueChanged">
|
||
|
<MemberSignature Language="C#" Value="protected override void OnValueChanged ();" />
|
||
|
<MemberSignature Language="ILAsm" Value=".method familyhidebysig virtual instance void OnValueChanged() cil managed" />
|
||
|
<MemberType>Method</MemberType>
|
||
|
<AssemblyInfo>
|
||
|
<AssemblyVersion>2.0.0.0</AssemblyVersion>
|
||
|
<AssemblyVersion>4.0.0.0</AssemblyVersion>
|
||
|
</AssemblyInfo>
|
||
|
<ReturnValue>
|
||
|
<ReturnType>System.Void</ReturnType>
|
||
|
</ReturnValue>
|
||
|
<Parameters />
|
||
|
<Docs>
|
||
|
<remarks>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>The <see cref="M:System.Diagnostics.SourceSwitch.OnValueChanged" /> method converts the new value of the <see cref="P:System.Diagnostics.Switch.Value" /> property to the integer representation of the matching field in the <see cref="T:System.Diagnostics.SourceLevels" /> enumeration, and then uses this integer to set the <see cref="P:System.Diagnostics.Switch.SwitchSetting" /> property.</para>
|
||
|
</remarks>
|
||
|
<summary>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>Invoked when the value of the <see cref="P:System.Diagnostics.Switch.Value" /> property changes.</para>
|
||
|
</summary>
|
||
|
</Docs>
|
||
|
</Member>
|
||
|
<Member MemberName="ShouldTrace">
|
||
|
<MemberSignature Language="C#" Value="public bool ShouldTrace (System.Diagnostics.TraceEventType eventType);" />
|
||
|
<MemberSignature Language="ILAsm" Value=".method public hidebysig instance bool ShouldTrace(valuetype System.Diagnostics.TraceEventType eventType) cil managed" />
|
||
|
<MemberType>Method</MemberType>
|
||
|
<AssemblyInfo>
|
||
|
<AssemblyVersion>2.0.0.0</AssemblyVersion>
|
||
|
<AssemblyVersion>4.0.0.0</AssemblyVersion>
|
||
|
</AssemblyInfo>
|
||
|
<ReturnValue>
|
||
|
<ReturnType>System.Boolean</ReturnType>
|
||
|
</ReturnValue>
|
||
|
<Parameters>
|
||
|
<Parameter Name="eventType" Type="System.Diagnostics.TraceEventType" />
|
||
|
</Parameters>
|
||
|
<Docs>
|
||
|
<remarks>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>This method is called by the Trace methods in the <see cref="T:System.Diagnostics.TraceSource" /> class to determine whether listeners should be called to write a trace.</para>
|
||
|
<block subset="none" type="note">
|
||
|
<para>Application code should not call this method; it is intended to be called only by methods in the <see cref="T:System.Diagnostics.TraceSource" /> class.</para>
|
||
|
</block>
|
||
|
</remarks>
|
||
|
<summary>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>Determines if trace listeners should be called, based on the trace event type.</para>
|
||
|
</summary>
|
||
|
<returns>
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />
|
||
|
<para>True if the trace listeners should be called; otherwise, false.</para>
|
||
|
</returns>
|
||
|
<param name="eventType">
|
||
|
<attribution license="cc4" from="Microsoft" modified="false" />One of the <see cref="T:System.Diagnostics.TraceEventType" /> values.</param>
|
||
|
</Docs>
|
||
|
</Member>
|
||
|
</Members>
|
||
|
</Type>
|