6.9 KiB
Voltmeter Unit{docsify-ignore-all}
SKU:U087
Description
Voltmeter Unit is a voltage meter that can monitor the voltage in real time. The 16-bit ADC (analog-to-digital) converter ADS1115 is used internally to communicate through I2C (0X49).
In order to ensure the measurement accuracy, there is a built-in DC-DC isolated power supply, and the I2C interface is also electrically isolated through the low-power isolator CA-IS3020S.
This prevents noise and surges on the data bus or other circuits from entering the local ground terminal to interfere or damage sensitive circuits. Each Unit is individually calibrated when leaving the factory, initial accuracy of 0.1%FS, ±1 count, and a maximum measurement voltage of ±36V.
?>EEPROM (0x53) has built-in calibration parameters when leaving the factory. Please do not write to the EEPROM, otherwise the calibration data will be overwritten and the measurement results will be inaccurate.
Product Features
- ±36V range
- LED power indicator
- 16-bit ADC conversion
- Resolution: Auto range, Count ≤ 16V, 1mV; Count > 16V, 7.9mV
- Inital accuracy 0.1%FS, ±1 count
- Built-in CA-IS3020S isolation chip, anti-interference
- Isolated DC-DC
- Up to 1000 VRMS isolation withstand voltage
- Development platform: Arduino, UIFlow (under development)
- 2x LEGO compatible holes
Includes
- 1x Voltmeter Unit
- 1x Grove Cable(20cm)
Application
- voltmeter
Specification
| Resources | Parameter |
| Resolution | Auto range, Count ≤ 16V, 1mV; Count > 16V, 7.9mV |
| Measuring range | ±36V |
| Inital Accurancy | 0.1%FS, ±1 count |
| Communication protocol | I2C:0x49 |
| Net Weight | 9g |
| Gross Weight | 24g |
| Product Size | 65*24*8mm |
| Package Size | 67*53*12mm |
Measurement Range Gain Setting
Different range resolution is different, the error value of the result is different, please set the appropriate range according to the needs.Do not write EEPROM.If you really want to save the custom calibration values to EEPROM,Using the following statement, the factory data will be lost once written
bool Voltmeter::saveCalibration2EEPROM(voltmeterGain_t gain, int16_t hope, int16_t actual)
//@Parameter: voltmeterGarin_t gain //Set Gain
###########################################
# // | PAG | Max Input Voltage(V) | #
# // | PAG_4096 | 128 | #
# // | PAG_2048 | 64 | #
# // | PAG_1024 | 32 | #
# // | PAG_512 | 16 | #
# // | PAG_256 | 8 | #
###########################################
//@Parameter: int16_t hope // Set target value
//@Parameter: int16_t actual //ADC raw value
| Voltage measurement range | Maximum input DC voltage(V) | Minimum resolution(mV) | Gain factor |
| PAG_4096(Calibrated) | ±128 | 7.85 | 0.125 |
| PAG_256(Calibrated) | ±8 | 0.49 | 0.007813 |
EasyLoader
EasyLoader is a concise and fast program writer, which has a built-in case program related to the product. It can be burned to the main control by simple steps to perform a series of function verification. Please install the corresponding driver according to the device type. M5Core host Please click here to view the CP210X driver installation tutorial, M5StickC/V/T/ATOM series can be used without driver)
Description:
Measuring voltage, gear 0.512, maximum measuring voltage 16V, analog pointer indicating range 5V
Related Link
- Datasheet
- CA-IS3020S
- ADS1115
Schematic
PinMap
| M5Core(GROVE A) | SDA(GPIO21) | SCL(GPIO22) | 5V | GND |
| V Meter Unit | SDA | SCL | 5V | GND |
Example
1. Arduino
2. UIFlow
Last updated: 2020-12-14