# ENV II

| Specification | Parameter |
|---|---|
| Max temperature measuring range | -40 ~ 120 ℃ |
| Typical temperature tolerance | 0 ~ 60 ℃/±0.2℃ |
| Humidity measuring range | 10 ~ 90 %RH / ±2% |
| Air pressure measuring range | 300 ~ 1100hPa / ±1hPa |
| Communication protocol | I2C:SHT30(0x44),BMP280(0x76) |
| Operating temperature range | 32°F to 104°F ( 0°C to 40°C ) |
| Net weight | 5g |
| Gross weight | 17g |
| Product Size | 24.2*32.2*8.1mm |
| Package Size | 67*53*12mm |
| Case material | Plastic ( PC ) |
| / | SHT30 | DHT12 |
|---|---|---|
| Max temperature measuring range | -40 ~ 120 ℃ | -20 ~ 60 ℃ |
| Typical temperature resolution | 0 ~ 60 ℃/±0.2℃ | ±0.2℃ |
| Humidity measuring range/resolution | 10 ~ 90 %RH / ±2% | 20 ~ 95 %RH/0.1% |
| M5Core(GROVE A) | GPIO22 | GPIO21 | 5V | GND |
| ENV II Unit | SCL | SDA | 5V | GND |
## Example