This was done entirely with mindless brute force, using
git grep -l '\<k[vmz]*alloc_objs*(.*, GFP_KERNEL)' |
xargs sed -i 's/\(alloc_objs*(.*\), GFP_KERNEL)/\1)/'
to convert the new alloc_obj() users that had a simple GFP_KERNEL
argument to just drop that argument.
Note that due to the extreme simplicity of the scripting, any slightly
more complex cases spread over multiple lines would not be triggered:
they definitely exist, but this covers the vast bulk of the cases, and
the resulting diff is also then easier to check automatically.
For the same reason the 'flex' versions will be done as a separate
conversion.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This is the result of running the Coccinelle script from
scripts/coccinelle/api/kmalloc_objs.cocci. The script is designed to
avoid scalar types (which need careful case-by-case checking), and
instead replace kmalloc-family calls that allocate struct or union
object instances:
Single allocations: kmalloc(sizeof(TYPE), ...)
are replaced with: kmalloc_obj(TYPE, ...)
Array allocations: kmalloc_array(COUNT, sizeof(TYPE), ...)
are replaced with: kmalloc_objs(TYPE, COUNT, ...)
Flex array allocations: kmalloc(struct_size(PTR, FAM, COUNT), ...)
are replaced with: kmalloc_flex(*PTR, FAM, COUNT, ...)
(where TYPE may also be *VAR)
The resulting allocations no longer return "void *", instead returning
"TYPE *".
Signed-off-by: Kees Cook <kees@kernel.org>
In cec_devnode_init(), the debugfs directory created with
debugfs_create_dir() is not removed if bus_register() fails.
This leaves a stale "cec" entry in debugfs and prevents
proper module reloading.
Fix this by removing the debugfs directory in the error path.
Fixes: a56960e8b4 ("[media] cec: add HDMI CEC framework (core)")
Cc: stable@vger.kernel.org
Signed-off-by: Haotian Zhang <vulab@iscas.ac.cn>
Signed-off-by: Hans Verkuil <hverkuil+cisco@kernel.org>
If rx-no-low-drive is set, then the CEC pin framework will disable
the detection of situations where a Low Drive has to be generated.
So if this is set, then we will never generate Low Drives.
This helps testing whether other CEC devices generate Low Drive
pulses by ensuring it is not us that is generating them.
Signed-off-by: Hans Verkuil <hverkuil@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
This adds support for inserting 'glitches' after a falling and/or
rising edge. This tests what happens when there are little voltage
spikes after falling or rising edges, which can be caused due to
noise or reflections on the CEC line.
A proper CEC implementation will deglitch this, but a poor implementation
can create a Low Drive pulse in response, effectively making CEC unusable.
Signed-off-by: Hans Verkuil <hverkuil@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
[Why]
There are several ns_to_ktime() calls that require using nanoseconds. It is
better to replace them with us_to_ktime() to make code clear, getting rid
of multiplication by 1000.
Also the timer function code may have an integer wrap-around issue. Since
both tx_custom_low_usecs and tx_custom_high_usecs can be set to up to
9999999 from the user space via cec_pin_error_inj_parse_line(), this may
cause usecs to be overflowed when adap->monitor_pin_cnt is zero and usecs
is multiplied by 1000.
[How]
Take advantage of using an appropriate helper func us_to_ktime() instead of
ns_to_ktime() to improve readability and to make the code clearer. And this
also mitigates possible integer wrap-arounds when usecs value is too large
and it is multiplied by 1000.
Found by Linux Verification Center (linuxtesting.org) with Svace.
Signed-off-by: Vitaliy Shevtsov <v.shevtsov@mt-integration.ru>
Signed-off-by: Hans Verkuil <hverkuil@xs4all.nl>
While the CEC adapter is configuring, it is not possible to transmit a
CEC message with the CEC_MSG_FL_RAW flag set as this is blocked at the
ioctl level. Check if this flag is set, and if so, allow the message to
be transmitted. This is useful for debugging if the display has no
physical address (typically because the HPD is pulled low while in
Standby).
Signed-off-by: Hans Verkuil <hverkuil@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
Having cec.h include linux/debugfs.h leads to all users of all cec
headers include and depend on debugfs.h and its dependencies for no
reason. Drop the include from cec.h, and include debugfs.h and
seq_file.h where needed.
Sort all the modified include lists while at it.
Signed-off-by: Jani Nikula <jani.nikula@intel.com>
Signed-off-by: Hans Verkuil <hverkuil@xs4all.nl>
no_llseek had been defined to NULL two years ago, in commit 868941b144
("fs: remove no_llseek")
To quote that commit,
At -rc1 we'll need do a mechanical removal of no_llseek -
git grep -l -w no_llseek | grep -v porting.rst | while read i; do
sed -i '/\<no_llseek\>/d' $i
done
would do it.
Unfortunately, that hadn't been done. Linus, could you do that now, so
that we could finally put that thing to rest? All instances are of the
form
.llseek = no_llseek,
so it's obviously safe.
Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Move cec_get/put_device to the media/cec.h header. This
allows CEC drivers to use this.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
The new CEC_MSG_FL_REPLY_VENDOR_ID flag only makes sense in combination
with CEC_MSG_VENDOR_COMMAND_WITH_ID. So rather than reporting an error
if that flag is set with another command, just clear the flag instead.
Only keep the message length check, since otherwise the flag would not
make sense.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
If this flag is set, then the reply is expected to consist of
the CEC_MSG_VENDOR_COMMAND_WITH_ID opcode followed by the Vendor ID (as
used in bytes 1-4 of the message), followed by the struct cec_msg reply
field.
Note that this assumes that the byte after the Vendor ID is a
vendor-specific opcode.
This flag makes it easier to wait for replies to vendor commands,
using the same CEC framework support for waiting for regular replies.
Support for this flag is indicated by setting the new
CEC_CAP_REPLY_VENDOR_ID capability.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
If the CEC device is unregistered, then an attempt to open
the device node should result in an -ENODEV error instead of
-ENXIO.
Document this as well in cec-func-open.rst.
This is consistent with the error code returned by other
file operations such as ioctl.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
The valid_la is used to check the length requirements,
including special cases of Timer Status. If the length is
shorter than 5, that means no Duration Available is returned,
the message will be forced to be invalid.
However, the description of Duration Available in the spec
is that this parameter may be returned when these cases, or
that it can be optionally return when these cases. The key
words in the spec description are flexible choices.
Remove the special length check of Timer Status to fit the
spec which is not compulsory about that.
Signed-off-by: Nini Song <nini.song@mediatek.com>
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Count how many Low Drive, Error and Arbitration Lost transmit
status errors occurred, and expose that in debugfs.
Also log the first 8 transmits that result in Low Drive or Error
conditions. That really should not happen with well-behaved CEC devices
and good HDMI cables.
This is useful to detect and debug HDMI cable issues.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab@kernel.org>