Steffen Klassert says:
====================
pull request (net-next): ipsec-next 2020-07-30
Please note that I did the first time now --no-ff merges
of my testing branch into the master branch to include
the [PATCH 0/n] message of a patchset. Please let me
know if this is desirable, or if I should do it any
different.
1) Introduce a oseq-may-wrap flag to disable anti-replay
protection for manually distributed ICVs as suggested
in RFC 4303. From Petr Vaněk.
2) Patchset to fully support IPCOMP for vti4, vti6 and
xfrm interfaces. From Xin Long.
3) Switch from a linear list to a hash list for xfrm interface
lookups. From Eyal Birger.
4) Fixes to not register one xfrm(6)_tunnel object twice.
From Xin Long.
5) Fix two compile errors that were introduced with the
IPCOMP support for vti and xfrm interfaces.
Also from Xin Long.
6) Make the policy hold queue work with VTI. This was
forgotten when VTI was implemented.
Please pull or let me know if there are problems.
====================
Signed-off-by: David S. Miller <davem@davemloft.net>
Rationale:
Reduces attack surface on kernel devs opening the links for MITM
as HTTPS traffic is much harder to manipulate.
Deterministic algorithm:
For each file:
If not .svg:
For each line:
If doesn't contain `\bxmlns\b`:
For each link, `\bhttp://[^# \t\r\n]*(?:\w|/)`:
If neither `\bgnu\.org/license`, nor `\bmozilla\.org/MPL\b`:
If both the HTTP and HTTPS versions
return 200 OK and serve the same content:
Replace HTTP with HTTPS.
Signed-off-by: Alexander A. Klimov <grandmaster@al2klimov.de>
Signed-off-by: Pablo Neira Ayuso <pablo@netfilter.org>
Introduce a mechanism that performs an handshake between the userspace
provider and kernel driver which verifies that the user supports all
required features in order to operate correctly.
The handshake verifies the needed functionality by comparing the reported
device caps and the provider caps. If the device reports a non-zero
capability the appropriate comp mask is required from the userspace
provider in order to allocate the context.
Link: https://lore.kernel.org/r/20200722140312.3651-4-galpress@amazon.com
Reviewed-by: Shadi Ammouri <sammouri@amazon.com>
Reviewed-by: Yossi Leybovich <sleybo@amazon.com>
Signed-off-by: Gal Pressman <galpress@amazon.com>
Signed-off-by: Jason Gunthorpe <jgg@nvidia.com>
This patch implements the tmr_notify callback for tcmu. When the callback
is called, tcmu checks the list of aborted commands it received as
parameter:
- aborted commands in the qfull_queue are removed from the queue and
target_complete_command is called
- from the cmd_ids of aborted commands currently uncompleted in cmd ring
it creates a list of aborted cmd_ids.
Finally a TMR notification is written to cmd ring containing TMR type and
cmd_id list. If there is no space in ring, the TMR notification is queued
on a TMR specific queue.
The TMR specific queue 'tmr_queue' can be seen as a extension of the cmd
ring. At the end of each iexecution of tcmu_complete_commands() we check
whether tmr_queue contains TMRs and try to move them onto the ring. If
tmr_queue is not empty after that, we don't call run_qfull_queue() because
commands must not overtake TMRs.
This way we guarantee that cmd_ids in TMR notification received by
userspace either match an active, not yet completed command or are no
longer valid due to userspace having complete some cmd_ids meanwhile.
New commands that were assigned to an aborted cmd_id will always appear on
the cmd ring _after_ the TMR.
Link: https://lore.kernel.org/r/20200726153510.13077-8-bstroesser@ts.fujitsu.com
Reviewed-by: Mike Christie <michael.christie@oracle.com>
Signed-off-by: Bodo Stroesser <bstroesser@ts.fujitsu.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Introduce a new fanotify_init() flag FAN_REPORT_NAME. It requires the
flag FAN_REPORT_DIR_FID and there is a constant for setting both flags
named FAN_REPORT_DFID_NAME.
For a group with flag FAN_REPORT_NAME, the parent fid and name are
reported for directory entry modification events (create/detete/move)
and for events on non-directory objects.
Events on directories themselves are reported with their own fid and
"." as the name.
The parent fid and name are reported with an info record of type
FAN_EVENT_INFO_TYPE_DFID_NAME, similar to the way that parent fid is
reported with into type FAN_EVENT_INFO_TYPE_DFID, but with an appended
null terminated name string.
Link: https://lore.kernel.org/r/20200716084230.30611-21-amir73il@gmail.com
Signed-off-by: Amir Goldstein <amir73il@gmail.com>
Signed-off-by: Jan Kara <jack@suse.cz>
For now, the flag is mutually exclusive with FAN_REPORT_FID.
Events include a single info record of type FAN_EVENT_INFO_TYPE_DFID
with a directory file handle.
For now, events are only reported for:
- Directory modification events
- Events on children of a watching directory
- Events on directory objects
Soon, we will add support for reporting the parent directory fid
for events on non-directories with filesystem/mount mark and
support for reporting both parent directory fid and child fid.
Link: https://lore.kernel.org/r/20200716084230.30611-19-amir73il@gmail.com
Signed-off-by: Amir Goldstein <amir73il@gmail.com>
Signed-off-by: Jan Kara <jack@suse.cz>
It was never enabled in uapi and its functionality is about to be
superseded by events FAN_CREATE, FAN_DELETE, FAN_MOVE with group
flag FAN_REPORT_NAME.
Keep a place holder variable name_event instead of removing the
name recording code since it will be used by the new events.
Link: https://lore.kernel.org/r/20200708111156.24659-17-amir73il@gmail.com
Signed-off-by: Amir Goldstein <amir73il@gmail.com>
Signed-off-by: Jan Kara <jack@suse.cz>
Parallel Redundancy Protocol (PRP) is another redundancy protocol
introduced by IEC 63439 standard. It is similar to HSR in many
aspects:-
- Use a pair of Ethernet interfaces to created the PRP device
- Use a 6 byte redundancy protocol part (RCT, Redundancy Check
Trailer) similar to HSR Tag.
- Has Link Redundancy Entity (LRE) that works with RCT to implement
redundancy.
Key difference is that the protocol unit is a trailer instead of a
prefix as in HSR. That makes it inter-operable with tradition network
components such as bridges/switches which treat it as pad bytes,
whereas HSR nodes requires some kind of translators (Called redbox) to
talk to regular network devices. This features allows regular linux box
to be converted to a DAN-P box. DAN-P stands for Dual Attached Node - PRP
similar to DAN-H (Dual Attached Node - HSR).
Add a comment at the header/source code to explicitly state that the
driver files also handles PRP protocol as well.
Signed-off-by: Murali Karicheri <m-karicheri2@ti.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
It's unusable from userland - it uses elf_gregset_t, which is not
provided by exported headers. glibc has it in sys/procfs.h, but
the same file defines struct elf_prstatus, so linux/elfcore.h can't
be included once sys/procfs.h has been pulled. Same goes for uclibc
and dietlibc simply doesn't have elf_gregset_t defined anywhere.
IOW, no userland source is including that thing.
Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
Add retrieval of the filesystem's metadata UUID to the fsinfo ioctl.
This is driven by setting the BTRFS_FS_INFO_FLAG_METADATA_UUID flag in
btrfs_ioctl_fs_info_args::flags.
Reviewed-by: Nikolay Borisov <nborisov@suse.com>
Signed-off-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Reviewed-by: David Sterba <dsterba@suse.com>
Signed-off-by: David Sterba <dsterba@suse.com>
Add retrieval of the filesystem's generation to the fsinfo ioctl. This is
driven by setting the BTRFS_FS_INFO_FLAG_GENERATION flag in
btrfs_ioctl_fs_info_args::flags.
Reviewed-by: Nikolay Borisov <nborisov@suse.com>
Signed-off-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Reviewed-by: David Sterba <dsterba@suse.com>
Signed-off-by: David Sterba <dsterba@suse.com>
With the recent addition of filesystem checksum types other than CRC32c,
it is not anymore hard-coded which checksum type a btrfs filesystem uses.
Up to now there is no good way to read the filesystem checksum, apart from
reading the filesystem UUID and then query sysfs for the checksum type.
Add a new csum_type and csum_size fields to the BTRFS_IOC_FS_INFO ioctl
command which usually is used to query filesystem features. Also add a
flags member indicating that the kernel responded with a set csum_type and
csum_size field.
For compatibility reasons, only return the csum_type and csum_size if
the BTRFS_FS_INFO_FLAG_CSUM_INFO flag was passed to the kernel. Also
clear any unknown flags so we don't pass false positives to user-space
newer than the kernel.
To simplify further additions to the ioctl, also switch the padding to a
u8 array. Pahole was used to verify the result of this switch:
The csum members are added before flags, which might look odd, but this
is to keep the alignment requirements and not to introduce holes in the
structure.
$ pahole -C btrfs_ioctl_fs_info_args fs/btrfs/btrfs.ko
struct btrfs_ioctl_fs_info_args {
__u64 max_id; /* 0 8 */
__u64 num_devices; /* 8 8 */
__u8 fsid[16]; /* 16 16 */
__u32 nodesize; /* 32 4 */
__u32 sectorsize; /* 36 4 */
__u32 clone_alignment; /* 40 4 */
__u16 csum_type; /* 44 2 */
__u16 csum_size; /* 46 2 */
__u64 flags; /* 48 8 */
__u8 reserved[968]; /* 56 968 */
/* size: 1024, cachelines: 16, members: 10 */
};
Fixes: 3951e7f050 ("btrfs: add xxhash64 to checksumming algorithms")
Fixes: 3831bf0094 ("btrfs: add sha256 to checksumming algorithm")
CC: stable@vger.kernel.org # 5.5+
Signed-off-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Reviewed-by: David Sterba <dsterba@suse.com>
Signed-off-by: David Sterba <dsterba@suse.com>
The qgroup level is limited to u16, so no need to use u64 for it.
Signed-off-by: Qu Wenruo <wqu@suse.com>
Reviewed-by: David Sterba <dsterba@suse.com>
Signed-off-by: David Sterba <dsterba@suse.com>
Add bpf_link-based API (bpf_xdp_link) to attach BPF XDP program through
BPF_LINK_CREATE command.
bpf_xdp_link is mutually exclusive with direct BPF program attachment,
previous BPF program should be detached prior to attempting to create a new
bpf_xdp_link attachment (for a given XDP mode). Once BPF link is attached, it
can't be replaced by other BPF program attachment or link attachment. It will
be detached only when the last BPF link FD is closed.
bpf_xdp_link will be auto-detached when net_device is shutdown, similarly to
how other BPF links behave (cgroup, flow_dissector). At that point bpf_link
will become defunct, but won't be destroyed until last FD is closed.
Signed-off-by: Andrii Nakryiko <andriin@fb.com>
Signed-off-by: Alexei Starovoitov <ast@kernel.org>
Link: https://lore.kernel.org/bpf/20200722064603.3350758-5-andriin@fb.com