The basic framework is based on the PowerPC OF code.
This code even tries to get the device addressing components
correct in the full path names.
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/cpufreq/cpufreq_ondemand.c: In function 'do_dbs_timer':
drivers/cpufreq/cpufreq_ondemand.c:374: warning: implicit declaration of function 'lock_cpu_hotplug'
drivers/cpufreq/cpufreq_ondemand.c:381: warning: implicit declaration of function 'unlock_cpu_hotplug'
drivers/cpufreq/cpufreq_conservative.c: In function 'do_dbs_timer':
drivers/cpufreq/cpufreq_conservative.c:425: warning: implicit declaration of function 'lock_cpu_hotplug'
drivers/cpufreq/cpufreq_conservative.c:432: warning: implicit declaration of function 'unlock_cpu_hotplug'
Cc: Dave Jones <davej@codemonkey.org.uk>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
Do a safer check for when to enable DMA. Currently we enable ISA DMA
for cases that do not need it, resulting in OOM conditions when ZONE_DMA
runs out of space.
Signed-off-by: Jens Axboe <axboe@suse.de>
They all duplicate macros to check for empty root and/or node, and
clearing a node. So put those in rbtree.h.
Signed-off-by: Jens Axboe <axboe@suse.de>
Otherwise we could be racing with truncate/mapping removal.
Problem found/fixed by Nick Piggin <npiggin@suse.de>, logic rewritten
by me.
Signed-off-by: Jens Axboe <axboe@suse.de>
- Remember to set ->last_sector so that the cfq_choose_req() logic
works correctly.
- Remove redundant call to cfq_choose_req()
Signed-off-by: Jens Axboe <axboe@suse.de>
This is a collection of patches that greatly improve CFQ performance
in some circumstances.
- Change the idling logic to only kick in after a request is done and we
are deciding what to do. Before the idling included the request service
time, so it was hard to adjust. Now it's true think/idle time.
- Take advantage of TCQ/NCQ/queueing for seeky sync workloads, but keep
it in control for sync and sequential (or close to) workloads.
- Expire queues immediately and move on to other busy queues, if we are
not going to idle after the current one finishes.
- Don't rearm idle timer if there are no busy queues. Just leave the
system idle.
Signed-off-by: Jens Axboe <axboe@suse.de>
Patch originally from Vasily Tarasov <vtaras@sw.ru>
If you set io-priority of process 1 using sys_ioprio_set system call by
another process 2 (like ionice do), then cfq_init_prio_data() function
sets priority of process 2 (current) on queue of process 1 and clears
the flag, that designates change of ioprio. So the process 1 will work
like with priority of process 2.
I propose not to call cfq_init_prio_data() on io-priority change, but
only mark queue as queue with changed prority. Every time when new
request comes cfq-scheduler checks for this flag and atomaticaly changes
priority of queue to new value.
Signed-off-by: Jens Axboe <axboe@suse.de>
A process flag to indicate whether we are doing sync io is incredibly
ugly. It also causes performance problems when one does a lot of async
io and then proceeds to sync it. Part of the io will go out as async,
and the other part as sync. This causes a disconnect between the
previously submitted io and the synced io. For io schedulers such as CFQ,
this will cause us lost merges and suboptimal behaviour in scheduling.
Remove PF_SYNCWRITE completely from the fsync/msync paths, and let
the O_DIRECT path just directly indicate that the writes are sync
by using WRITE_SYNC instead.
Signed-off-by: Jens Axboe <axboe@suse.de>
We cannot update them if the user changes nr_requests, so don't
set it in the first place. The gains are pretty questionable as
well. The batching loss has been shown to decrease throughput.
Signed-off-by: Jens Axboe <axboe@suse.de>