Pull input fixes from Dmitry Torokhov:
"The main change is support for keyboards and touchpads found in 2015
editions of Macbooks"
* 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/dtor/input:
Revert "Input: zforce - don't overwrite the stack"
Input: bcm5974 - add support for the 2015 Macbook Pro
HID: apple: Add support for the 2015 Macbook Pro
Input: bcm5974 - prepare for a new trackpad generation
Input: synaptics - dump ext10 capabilities as well
Current implementation of cp2112_raw_event() only accepts one data report at a
time. If last received data report is not fully handled yet, a new incoming
data report will overwrite it. In such case we don't guaranteed to propagate
the correct incoming data.
The trivial fix implemented here forces a single report at a time by requesting
in cp2112_read() no more than 61 byte of data, which is the payload size of a
single data report.
Cc: stable@vger.kernel.org
Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com>
Tested-by: Ellen Wang <ellen@cumulusnetworks.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
Commit 862cf55 ("HID: wacom: Introduce a new WACOM_DEVICETYPE_PAD device_type")
neglected to set the WACOM_DEVICETYPE_PAD flag for older two-finger Bamboo
Touch tablets. Not only does this result in the pad device not appearing when
such a tablet is plugged in, but also causes a segfault when 'wacom_bpt_touch'
tries to send pad events. This patch adds the flag to resolve these issues.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
Fields like HID_DG_CONTACTCOUNT are outside of the physical collection,
but within the application collection and report ID. Make sure to catch
those fields that are not part of the mt_report_id and return 0 so they
can be processed with the pen. Otherwise, the wrong HID_DG_CONTACTCOUNT
will be applied to cc_index and result in dereferencing a null pointer in
mt_touch_report.
Signed-off-by: Brent Adam <brentadam@smarttech.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
The newer firmware on MS Surface 2 tablets causes the type and touch cover keyboards to timeout when waiting for reports.
The quirk HID_QUIRK_NO_INIT_REPORTS allows them to function normally.
Signed-off-by: Reyad Attiyat <reyad.attiyat@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Use kernel.h macro definition.
Thanks to Julia Lawall for Coccinelle scripting support.
Signed-off-by: Fabian Frederick <fabf@skynet.be>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Adding support for the Microsoft Surface Pro Power Cover.
Signed-off-by: Raimund Roth <raimundmroth@gmail.gom>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Instead of having a single 'input_dev' device that will take either pen
or touch data depending on the type of the device, create seperate devices
devices for each. By splitting things like this, we can support devices
(e.g. the I2C "AES" sensors in some newer tablet PCs) that send both pen
and touch reports from a single endpoint.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This splits the 'wacom_setup_pentouch_input_capabilites' function into
pieces dedicated to doing setup for just the pen interface and just
the touch interface. This makes it easier to focus on the relevant
piece when making changes.
This patch introduces no functional changes.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Historically, both the touch and pad tools would have shared the
'BTN_TOOL_FINGER' type. Any time you needed to distinguish the two, you
had to use some other bit of knowledge (e.g. that the pad was on the same
interface as the pen, and thus 'touch_max' would be zero).
To make these checks more readable, we introduce WACOM_DEVICETYPE_PAD.
Although we still have to rely on other bits of knowledge to set this
bit on the right interface (since it cannot be detected from the HID
descriptor), it can be done just once inside 'wacom_setup_device_quirks'.
This patch introduces no functional changes.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The USB devices that this driver has historically supported segregate the
pen and touch portions of the tablet. Oftentimes the segregation would be
done at the interface level, though on occasion (e.g. Cintiq 24HDT) the
tablet would combine two totally independent USB devices behind an internal
USB hub. Because pen and touch never shared the same interface, it made
sense for the 'device_type' to store a single value: "pen" or "touch".
Recently, however, some I2C devices have been created which combine the
two. A first step to accomodating this is to expand 'device_type' so that
it can represent two (or potentially more) types simultaneously. To do
this, we treat it as a bitfield and set/check individual bits rather
than using the '=' and '==' operators.
This should not result in any functional change since no supported devices
(that I'm aware of, at least) have HID descriptors that indicate both
pen and touch reports on a single interface.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
A little bit of cleanup work for 'wacom_update_name' to make it easier on
the eyes. Creates a temporary 'name' variable on which we'll perform our
edits. Once the name is in its final form, it will be copied (with
appropriate suffix) to 'wacom_wac->name' and 'wacom_wac->pad_name'.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Physical buttons do not use F30 to report their state and in some cases the
data reported in F30 is incorrect and inconsistent with what is reported by
the HID descriptor. When physical buttons are present, ignore F30 and let
hid-input report buttons based on what is defined in the HID descriptor.
Signed-off-by: Andrew Duggan <aduggan@synaptics.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Update Kconfig with enhanced help text for hid-plantronics driver.
Update hid-plantronics.c to identify device type and correctly map
either the vendor unique or consumer control volume up/down usages
to KEY_VOLUMEUP and KEY_VOLUMEDOWN events. Unmapped usages are ignored
to prevent core mapping of unknown usages to random mouse events.
Tested on ChromeBox/ChromeBook with various Plantronics devices.
Signed-off-by: Terry Junge <terry.junge@plantronics.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Fix the report descriptor so that the buttons and trigger are correctly reported.
The format of the input report is described here:
https://github.com/nitsch/moveonpc/wiki/Input-report
The Accelerometers and Gyros (1st frame only) are also reported as axis, but
the Magnetometers are NOT as 'fixing' their byte order would break user-space
drivers such as PSMoveAPI.
It is hoped to resolve this at a future time.
Signed-off-by: Simon Wood <simon@mungewell.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The LED and Rumble control only function via BT if the full output report
is sent. The large report still functions via USB.
Signed-off-by: Simon Wood <simon@mungewell.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Add support for the battery charge level and state to be read via BT.
This is not support via USB as there is no know way to get the device
sending 'input' reports over USB.
Signed-off-by: Simon Wood <simon@mungewell.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Split quirk for PS Move Controller as it has to be treated differently
when connected via BT.
Signed-off-by: Simon Wood <simon@mungewell.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>