commit 973e9a2795 upstream.
If the regulator constraints are empty and there is no voltage
reported then nothing will be added to the text displayed for the
constraints, leading to random stack data being printed. This is
unlikely to happen for practical regulators since most will at
least report a voltage but should still be fixed.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
commit a2fad9bf26 upstream.
The WM8350 LED driver needs to be able to enable and disable the
regulators it is using. Previously the core wasn't properly enforcing
status change constraints so the driver was able to function but this
has always been intended to be required.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
If ret is unsigned, the checks for negative wm831x_reg_read() return values
are wrong. The error value should be transmitted to its caller, e.g.
wm831x_gp_ldo_get_status() which tests for a negative return value.
Signed-off-by: Roel Kluin <roel.kluin@gmail.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This makes _regulator_enable() properly handle the case where
a regulator is already on when you try to enable it. Currently
it will erroneously handle positive return values as an error.
Signed-off-by: Linus Walleij <linus.walleij@stericsson.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Fixes the following errors on both tps650xx regulator drivers :-
drivers/regulator/tps65023-regulator: struct i2c_device_id is 32 bytes. The last of 1 is:
0x74 0x70 0x73 0x36 0x35 0x30 0x32 0x33 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
FATAL: drivers/regulator/tps65023-regulator: struct i2c_device_id is not terminated with a NULL entry!
This patch also fixes the GPL v2 licence string for both drivers.
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Now fixed regulators that have their enable pin connected to a GPIO line
can use the fixed regulator driver for regulator enable/disable control.
The GPIO number and polarity information is passed through platform data.
GPIO enable control is achieved using gpiolib.
Signed-off-by: Roger Quadros <ext-roger.quadros@nokia.com>
Reviewed-by: Philipp Zabel <philipp.zabel@gmail.com>
Reviewed-by: Felipe Balbi <felipe.balbi@nokia.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This patch implements list_voltage for the pcf50644 regulator driver.
As the voltages are linearly scaled the code to convert register values to
voltages can be reused and most of the code can be shared with get_voltage.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
The regulator_enable() code wasn't actually checking that the
machine constraints had given permission to enable the regulator.
Add code to do that, but only if the regulator is not already on
due to something like always_on or being left on at startup since
in those cases there's no physical change being introduced and the
constraint wouldn't make any sense.
Also add matching code for disable(). We need to do less there since
either regulator_enable() should have succeeded first or the board
setup makes no sense.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>