The bq25890_charger code supports enabling/disabling the boost converter
based on usb-phy notifications. But the usb-phy framework is not used on
all boards/platforms. At support for registering the Vbus boost converter
as a standard regulator when there is no usb-phy on the board.
Also add support for providing regulator_init_data through platform_data
for use on boards where device-tree is not used and the platform code must
thus provide the regulator_init_data.
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Pull ARM SoC driver updates from Arnd Bergmann:
"These are updates for drivers that are tied to a particular SoC,
including the correspondig device tree bindings:
- A couple of reset controller changes for unisoc, uniphier, renesas
and zte platforms
- memory controller driver fixes for omap and tegra
- Rockchip io domain driver updates
- Lots of updates for qualcomm platforms, mostly touching their
firmware and power management drivers
- Tegra FUSE and firmware driver updateѕ
- Support for virtio transports in the SCMI firmware framework
- cleanup of ixp4xx drivers, towards enabling multiplatform support
and bringing it up to date with modern platforms
- Minor updates for keystone, mediatek, omap, renesas"
* tag 'drivers-5.15' of git://git.kernel.org/pub/scm/linux/kernel/git/soc/soc: (96 commits)
reset: simple: remove ZTE details in Kconfig help
soc: rockchip: io-domain: Remove unneeded semicolon
soc: rockchip: io-domain: add rk3568 support
dt-bindings: power: add rk3568-pmu-io-domain support
bus: ixp4xx: return on error in ixp4xx_exp_probe()
soc: renesas: Prefer memcpy() over strcpy()
firmware: tegra: Stop using seq_get_buf()
soc/tegra: fuse: Enable fuse clock on suspend for Tegra124
soc/tegra: fuse: Add runtime PM support
soc/tegra: fuse: Clear fuse->clk on driver probe failure
soc/tegra: pmc: Prevent racing with cpuilde driver
soc/tegra: bpmp: Remove unused including <linux/version.h>
dt-bindings: soc: ti: pruss: Add dma-coherent property
soc: ti: Remove pm_runtime_irq_safe() usage for smartreflex
soc: ti: pruss: Enable support for ICSSG subsystems on K3 AM64x SoCs
dt-bindings: soc: ti: pruss: Update bindings for K3 AM64x SoCs
firmware: arm_scmi: Use WARN_ON() to check configured transports
firmware: arm_scmi: Fix boolconv.cocci warnings
soc: mediatek: mmsys: Fix missing UFOE component in mt8173 table routing
soc: mediatek: mmsys: add MT8365 support
...
Prepared by checking the datasheets of max17042, max17047/50
and max170455 for differences in register maps.
Signed-off-by: Sebastian Krzyszkowiak <sebastian.krzyszkowiak@puri.sm>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
For the smartreflex device, we need to disable smartreflex on SoC idle,
and have been using pm_runtime_irq_safe() to do that. But we want to
remove the irq_safe usage as PM runtime takes a permanent usage count
on the parent device with it.
In order to remove the need for pm_runtime_irq_safe(), let's gate
the clock directly in the driver. This removes the need to call PM runtime
during idle, and allows us to switch to using CPU_PM in the following
patch.
Note that the smartreflex interconnect target module is configured for smart
idle, but the clock does not have autoidle capability, and needs to be gated
manually. If the clock supported autoidle, we would not need to even gate
the clock.
With this change, we can now remove the related quirk flags for ti-sysc
also.
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Santosh Shilimkar <santosh.shilimkar@oracle.com>
Add support for TI BQ78Z100, I2C interface gas gauge.
It provides a fully integrated safety protection
and authentication for 1 to 2-series cell Li-Ion and
Li-Polymer battery packs.
The patch was tested with BQ78Z100 equipment.
CASE I: Discharging:
POWER_SUPPLY_NAME=bq78z100-0
POWER_SUPPLY_STATUS=Discharging
POWER_SUPPLY_PRESENT=1
POWER_SUPPLY_VOLTAGE_NOW=3386000
POWER_SUPPLY_CURRENT_NOW=-5000
POWER_SUPPLY_CAPACITY=27
POWER_SUPPLY_CAPACITY_LEVEL=Normal
POWER_SUPPLY_TEMP=269
POWER_SUPPLY_TIME_TO_EMPTY_NOW=1249920
POWER_SUPPLY_TECHNOLOGY=Li-ion
POWER_SUPPLY_CHARGE_FULL=6494000
POWER_SUPPLY_CHARGE_NOW=1736000
POWER_SUPPLY_CHARGE_FULL_DESIGN=6000000
POWER_SUPPLY_CYCLE_COUNT=1
POWER_SUPPLY_POWER_AVG=-20000
POWER_SUPPLY_HEALTH=Good
POWER_SUPPLY_MANUFACTURER=Texas Instruments
CASE II : No discharging current:
POWER_SUPPLY_NAME=bq78z100-0
POWER_SUPPLY_STATUS=Not charging
POWER_SUPPLY_PRESENT=1
POWER_SUPPLY_VOLTAGE_NOW=3386000
POWER_SUPPLY_CURRENT_NOW=0
POWER_SUPPLY_CAPACITY=27
POWER_SUPPLY_CAPACITY_LEVEL=Normal
POWER_SUPPLY_TEMP=270
POWER_SUPPLY_TECHNOLOGY=Li-ion
POWER_SUPPLY_CHARGE_FULL=6494000
POWER_SUPPLY_CHARGE_NOW=1734000
POWER_SUPPLY_CHARGE_FULL_DESIGN=6000000
POWER_SUPPLY_CYCLE_COUNT=1
POWER_SUPPLY_POWER_AVG=0
POWER_SUPPLY_HEALTH=Good
POWER_SUPPLY_MANUFACTURER=Texas Instruments
Signed-off-by: LI Qingwu <Qing-wu.Li@leica-geosystems.com.cn>
Reviewed-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
On all newer bq27xxx ICs, the AveragePower register contains a signed
value; in addition to handling the raw value as unsigned, the driver
code also didn't convert it to µW as expected.
At least for the BQ28Z610, the reference manual incorrectly states that
the value is in units of 1mW and not 10mW. I have no way of knowing
whether the manuals of other supported ICs contain the same error, or if
there are models that actually use 1mW. At least, the new code shouldn't
be *less* correct than the old version for any device.
power_avg is removed from the cache structure, se we don't have to
extend it to store both a signed value and an error code. Always getting
an up-to-date value may be desirable anyways, as it avoids inconsistent
current and power readings when switching between charging and
discharging.
Signed-off-by: Matthias Schiffer <matthias.schiffer@ew.tq-group.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This driver uses platform data to pass GPIO lines using the
deprecated global GPIO numbers. There are no in-tree users
of this platform data.
Any out-of-tree or coming users of this driver can easily be
migrated to use machine descriptor tables as described in
Documentation/driver-api/gpio/board.rst
section "platform data".
Cc: Anish Kumar <anish198519851985@gmail.com>
Cc: H. Nikolaus Schaller <hns@goldelico.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Add support for new device: the TI bq34z100-G1, a Wide Range Fuel Gauge
for Li-Ion, PbA, NiMH, and NiCd batteries. The device shares a lot with
other models, although it has its own differences requiring new quirks.
This patch was tested on a system equipped with NiMH batteries.
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
In commit 830ae44220 ("extcon: Remove the deprecated extcon functions")
the function extcon_register_interest became a no-op returning an error,
leading to non-functional behaviour in charger-manager.
Additionally, a translation table is needed between the text representation
of the extcon cable names and their IDs is needed. In order to retain DT
compatibility, TA and CHARGE-DOWNSTREAM are added as they were present up
until commit 11eecf910b ("extcon: Modify the id and name of external
connector")
Signed-off-by: Jonathan Bakker <xc-racer2@live.ca>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
cm_monitor(), where charging management starts, checks various charging
condition sequentially to decide next charging operation. However, as it
follows sequential process, cascaded if statements, it does some
jobs which have already done in the previous stage. This results in a
delay in decision making. Moreover, starting point of charging is spread
all around which makes maintain code and debugging difficult.
Both of the problems mentioned above become clean if it manages battery
charging focusing on battery status not following sequential condition
checking. Now, cm_monitor() moves battery state diagram and does the
optimal operation for current state. As a result, it reduces whole
monitoring time almost in half.
Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: Jonathan Bakker <xc-racer2@live.ca>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
cm_notify_event() was introduced to get an event associated with the
battery status externally (ie in board files), but no one ever used it.
Moreover it makes charger manager driver more complicated. Drop the
function and all data related to it to simplify the driver.
Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: Jonathan Bakker <xc-racer2@live.ca>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Add the Texas Instruments BQ28z610 battery monitor.
The register address map is laid out the same as compared to other
devices within the file.
The battery status register bits are similar to the bq27z561 but they
are different compared to other fuel gauge devices within this file.
Signed-off-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Add the Texas Instruments BQ27Z561 battery monitor. The register address
map is laid out the same as compared to other devices within the file.
The battery status register has differing bits to determine if the
battery is full, discharging or dead.
Signed-off-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The omap_sr_pdata is not declared but is exported, so add a
define for it to fix the following warning:
arch/arm/mach-omap2/pdata-quirks.c:609:36: warning: symbol 'omap_sr_pdata' was not declared. Should it be static?
Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>