Implement the suspend/resume procedure for the Broadcom AC131 and BCM5241 type
of PHYs (10/100 only) by entering the standard power down followed by the
proprietary standby mode in the auxiliary mode 4 shadow register. On resume,
the PHY software reset is enough to make it come out of standby mode so we can
utilize brcm_fet_config_init() as the resume hook.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add support for BCM53128 internal PHYs. These support interrupts as well as
statistics. Therefore, enable the Broadcom PHY driver for them.
Tested on BCM53128 switch using the mainline b53 DSA driver.
Signed-off-by: Kurt Kanzenbach <kurt@linutronix.de>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
7712 is a 16nm process SoC with a 10/100 integrated Ethernet PHY,
utilize the recently defined 16nm EPHY macro to configure that PHY.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
An extraneous number was added during the inclusion of that change,
correct that such that we use a single bit as is expected by the PHY
driver.
Reported-by: Justin Chen <justinpopo6@gmail.com>
Fixes: d6da08ed14 ("net: phy: broadcom: Add IDDQ-SR mode")
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add support for putting the PHY into IDDQ Soft Recovery mode by setting
the TOP_MISC register bits accordingly. This requires us to implement a
custom bcm54xx_suspend() routine which diverges from genphy_suspend() in
order to configure the PHY to enter IDDQ with software recovery as well
as avoid doing a read/modify/write on the BMCR register.
Doing a read/modify/write on the BMCR register means that the
auto-negotation bit may remain which interferes with the ability to put
the PHY into IDDQ-SR mode. We do software reset upon suspend in order to
put the PHY back into its state prior to suspend as recommended by the
datasheet.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Enable the DAC early wake when then link operates at 10BaseT allows
power savings in the hundreds of milli Watts by shutting down the
transmitter. A number of errata have been issued for various Gigabit
PHYs and the recommendation is to enable both the early and forced DAC
wake to be on the safe side. This needs to be done dynamically based
upon the link state, which is why a link_change_notify callback is
utilized.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Link: https://lore.kernel.org/r/20210916212742.1653088-1-f.fainelli@gmail.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
The tg3 driver tried to communicate towards the PHY driver whether it
wanted RGMII in-band signaling enabled or disabled however there is
nothing that looks at those flags in drivers/net/phy/broadcom.c so this
does do not anything.
Suggested-by: Vladimir Oltean <olteanv@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
BCM54210E/BCM50212E has been verified to work correctly with the
auto-power down configuration done by bcm54xx_adjust_rxrefclk(), add it
to the list of PHYs working.
While we are at it, provide an appropriate name for the bit we are
changing which disables the RXC and TXC during auto-power down when
there is no energy on the cable.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Vladimir Oltean <olteanv@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
We have a number of unused flags defined today and since we are scarce
on space and may need to introduce new flags in the future remove and
shift every existing flag down into a contiguous assignment.
PHY_BCM_FLAGS_MODE_1000BX was only used internally for the BCM54616S
PHY, so we allocate a driver private structure instead to store that
flag instead of canibalizing one from phydev->dev_flags for that
purpose.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Vladimir Oltean <olteanv@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
BCM72113 features a 28nm integrated EPHY, add an entry to the driver for
it.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
The BCM54811 PHY shares many similarities with the already supported BCM54810
PHY but additionally requires some semi-unique configuration.
Signed-off-by: Kevin Lo <kevlo@kevlo.org>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Most modern broadcom PHYs support ECD (enhanced cable diagnostics). Add
support for it in the bcm-phy-lib so they can easily be used in the PHY
driver.
There are two access methods for ECD: legacy by expansion registers and
via the new RDB registers which are exclusive. Provide functions in two
variants where the PHY driver can choose from. To keep things simple for
now, we just switch the register access to expansion registers in the
RDB variant for now. On the flipside, we have to keep a bus lock to
prevent any other non-legacy access on the PHY.
The results of the intra-pair tests are inconclusive (at least for the
BCM54140). Most of the times half the length is reported but sometimes
the length is correct.
Signed-off-by: Michael Walle <michael@walle.cc>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
This PHY has two PHY IDs depending on its mode. Adjust the mask so that
it includes both IDs.
Signed-off-by: Michael Walle <michael@walle.cc>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The Broadcom BCM54140 is a Quad SGMII/QSGMII Copper/Fiber Gigabit
Ethernet transceiver.
This also adds support for tunables to set and get downshift and
energy detect auto power-down.
The PHY has four ports and each port has its own PHY address.
There are per-port registers as well as global registers.
Unfortunately, the global registers can only be accessed by reading
and writing from/to the PHY address of the first port. Further,
there is no way to find out what port you actually are by just
reading the per-port registers. We therefore, have to scan the
bus on the PHY probe to determine the port and thus what address
we need to access the global registers.
Signed-off-by: Michael Walle <michael@walle.cc>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
RDB (Register Data Base) registers are used on newer Broadcom PHYs. Add
helper to read, write and modify these registers.
Signed-off-by: Michael Walle <michael@walle.cc>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
BCM53125 has internal Gigabit PHYs which support interrupts as well as
statistics, make it possible to configure both of those features with a
PHY driver entry.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The BCM54616S PHY cannot work properly in RGMII->1000Base-X mode, mainly
because genphy functions are designed for copper links, and 1000Base-X
(clause 37) auto negotiation needs to be handled differently.
This patch enables 1000Base-X support for BCM54616S by customizing 3
driver callbacks, and it's verified to be working on Facebook CMM BMC
platform (RGMII->1000Base-KX):
- probe: probe callback detects PHY's operation mode based on
INTERF_SEL[1:0] pins and 1000X/100FX selection bit in SerDES 100-FX
Control register.
- config_aneg: calls genphy_c37_config_aneg when the PHY is running in
1000Base-X mode; otherwise, genphy_config_aneg will be called.
- read_status: calls genphy_c37_read_status when the PHY is running in
1000Base-X mode; otherwise, genphy_read_status will be called.
Note: BCM54616S PHY can also be configured in RGMII->100Base-FX mode, and
100Base-FX support is not available as of now.
Signed-off-by: Tao Ren <taoren@fb.com>
Acked-by: Vladimir Oltean <olteanv@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Previously the green and amber LEDs on this quad PHY were solid, to
indicate an encoding of the link speed (10/100/1000).
This keeps the LEDs always on just as before, but now they flash on
Rx/Tx activity.
Signed-off-by: Vladimir Oltean <olteanv@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
BCM54612E have 4 multi-functional LED pins that can be configured
through register setting; the LED4 pin can be configured to a 125MHz
reference clock output by setting the spare register. Since the dedicated
CLK125 reference clock pin is not brought out on the 48-Pin MLP, the LED4
pin is the only pin to provide such function in this package, and therefore
it is beneficial to just enable the reference clock by default.
Signed-off-by: Kun Yi <kunyi@google.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>