The min_uV and max_uV are not really used in the code and misleading because
the min_uV and max_uV settings does not match the value in the voltage table.
For example, we have
static const unsigned int ldo_vaux3_voltages[] = {
1200000,
1500000,
1800000,
2100000,
2500000,
2750000,
2790000,
2910000,
};
With below min_uV/max_uV settings for AB8500_LDO_AUX3.
.min_uV = 1100000,
.max_uV = 3300000,
The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2
and is wrong.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops
because the voltage won't change. ( And ab8500_regulator_fixed_ops does not
implement get_voltage_sel so set_voltage_time_sel won't be called )
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0]
falls with min_uV and max_uV.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For linear mappings, we can use below equation to get the voltage difference
between new_selector and old_selector:
abs(new_selector - old_selector) * rdev->desc->uV_step
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Reuse map_voltage() to get the selector of a given uV.
Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val().
Also remove unused wm8350_dcdc_val_to_mvolts() function.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage
falls within specified range.
Use wm8350_ldo_list_voltage() here is less error prone.
wm8350_ldo_val_to_mvolts() is only used in wm8350_ldo_list_voltage now, so
remove it and move the implementation to wm8350_ldo_list_voltage().
This patch also include below small changes in wm8350_ldo_map_voltage:
1. wm8350_ldo_map_voltage() returns selector, thus rename variable mV to sel.
2. Use DIV_ROUND_UP macro to calculate selector.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch converts .is_enabled and .get_voltage_sel to
regulator_is_enabled_regmap and regulator_get_voltage_sel_regmap.
For .enable, .disable, and .set_voltage_sel, the write protect level is either
1 or 2. So we cannot use regulator_[enable|disable|set_voltage_sel]_regmap.
Now we store the enable reg/mask and vsel reg/mask in regulator_desc,
so we can remove enable_mask, set_vout_reg, and set_vout_mask from
struct tps_info.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Adjust the equation for selector >= 15 for better readability.
The equation "1700000 + ((selector - 15) * 100000)" can be interpreted by:
Starting from selector 15: Steps of 100mV from 1700mV
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Call wm8400_ldo_list_voltage() instead of open code to verify selected voltage
falls within specified range.
Use wm8400_ldo_list_voltage() here is less error prone.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV.
The unit of ramp_delay is mV/us.
Current code multiples 1000 at wrong place.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV.
The unit of ramp_rate is mV/us.
Thus 1000 should be multiplied.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Reviewed-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch adds regulator_set_voltage_time_sel(), to move into core, the
commonly used code by drivers to provide the .set_voltage_time_sel callback.
It will also allow us to configure different ramp delay for different
regulators easily.
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
If this driver only works when pdata->num_regulators == MAX77686_REGULATORS,
let's check it earlier.
Also remove unused num_regulators from struct max77686_data.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Also adds tps6586x_ldo0_voltages mapping table for LDO0, so we can remove the
hack in tps6586x_list_voltage() and convert it to regulator_list_voltage_table.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>