The service parameters for the VPI/RPIs were incorrect, resulting in
lower utilization
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
T10 Diff fixes and enhancements:
- Add SLI4 Lancer support for T10 DIF / BlockGuard (121980)
- Fix SLI4 BlockGuard behavior when protection data is generated by HBA (121980)
- Enhance debugfs for injecting T10 DIF errors (123966, 132966)
- Fix Incorrect usage of bghm for BlockGuard errors (127022)
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
SLI related fixes:
- Fix REG_RPI fails on SLI4 HBA putting NPort into NPR state (126230)
- Fix ELS FDISC failing with local reject / invalid RPI. (126350)
- Fix reset port when reset is needed during fw_dump (125807)
- Fix unbounded firmware revision string from port cause panic (126560)
- Fix driver behavior when receiving an ADISC (126654)
- Fix driver not returning when bad ndlp found in abts error event
handling (126209)
- Add more driver logs in area of SLI4 port error attention and reset
recovery (126813, 124466)
- Fix failure in handling large CQ/EQ identifiers in an IOV
environment (126856)
- Fix for driver using duplicate RPIs after lancer port reset (126723)
- Clear vport->fc_myDID in lpfc_els_issue_fdisc to guarentee a
zero SID (126779, 126897)
- Fix for SLI4 Port delivery for BLS ABORT ACC (126289)
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
- Add Basic support for SLI4 Loopback.
(CR 124951, 125766, 124951, 125843, 125832, 125843)
- Added missing protection in setting/clearing of phba->link_flag bit
field (CR 125994)
- Use link type and link number obtained from READ_CONFIG mailbox
command. (CR 126264)
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
FC and SCSI Discovery Fixes:
- Clear the virtual fabrics bit (word 1 bit 30) when sending the FLOGI
and FDISC. (CR 124339)
- Return a MLQUEUE_DEVICE_BUSY if the driver detects that an I/O is being
retried too quickly (CR 124668)
- Remove NDLP reference put in lpfc_cmpl_els_logo_acc for all but fabric
nodes (CR 123924)
- Only retry FDISCs every second and stop retrying after devloss number
of retries (CR 13939)
- Check to see if vports are unloading before adding them to the vport
work array. (CR 124996)
- Fixed illegal state transition during driver unload (CR 124191)
- Added missing protection on setting/clearing of vport->fc_flag bit (CR 126002)
- Set NPIV flag in lpfc_mbx_process_link_up for all ports sli3 and
above. (CR 126094)
- Clear FCP command bytes that are not used. (CR 126209)
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>