The Win 8 protocol specify the fact that each valid touch must be reported
within a frame until it is released.
We can therefore use the always_valid quirk and dismiss reports when we see
duplicate contacts ID.
We recognize Win8 certified devices from their vendor feature 0xff0000c5
where Microsoft put a signed blob in the report to check if the device
passed the certification.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 devices supporting hovering must provides InRange HID field.
The information that the finger is here but is not touching the surface
is sent to the user space through ABS_MT_DISTANCE as required by the
multitouch protocol.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This quirk allows a device to reuse a contact id when sending garbage
inactive contacts at the end of a report.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win 8 device specification changed the requirements for the hid usages
of the multitouch devices. Now InRange is optional and must be only
used when the device supports hovering.
This ensures that the quirk ALWAYS_VALID is taken into account and
also ensures its precedence over the other VALID* quirks.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 input specification clarifies the X and Y sent by devices.
It distincts the position where the user wants to Touch (T) from
the center of the ellipsoide (C). This patch enable supports for this
distinction in hid-multitouch.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 devices are required to present the feature "Maximum Contact Number".
Fortunately all win7 devices I've seen presents this feature.
If the current value is 0, then, the driver can get the actual supported
contact count by refering to the logical_max.
This win8 specification ensures that logical_max may not be above 250.
This also allows us to detect when devices like irtouch or stantum reports
an obviously wrong value of 255.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Acked-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 certification introduced the ability to transmit two X and two Y per
touch. The specification precises that it must be used in an array.
This test guarantees that we split the touches on the last element
in this array.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Exporting the function allows us to calculate the resolution in third
party drivers like hid-multitouch.
This patch also complete the function with additional valid axes.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Fix maxcontacts problem for PWT GeneralTouch multi-touchscreen.
Our device didn't contain HID_DG_CONTACTMAX usage. This usage use to describe
touchscreen's maxcontacts for hid-multitouch.c to get maxcontacts automatic. We
fix the device that driver can get maxcontact from our device, hence it doesn't
need .maxcontact=10. Now there is just one device class can fix all our PWT
touchscreen.
Signed-off-by: Xianhan Yu <aroundight77@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Fix the touch-up no response problem on GeneralTouch twofingers touchscreen and
modify the driver for new GeneralTouch PWT touchscreen.
Signed-off-by: Xianhan Yu <aroundight77@gmail.com>
Reviewed-by Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Add support for the Flatfrog Multitouch 3200 panel. This panel
advertises some fields that it does not use, hence the new quirk.
Cc: Pablo Cases <pablo.cases@flatfrog.com>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Some devices report the number of contacts via the unreliable
CONTACTCOUNT usage, rather than using the CONTACTMAX feature.
Without this patch, the 3M devices are constrained to the default
maximum of ten fingers.
Cc: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
With the input_mt_sync_frame() function in place, there is no longer
any need to keep the full touch state in the driver. This patch
removes the slot state and replaces the lookup code with the input-mt
equivalent.
Reviewed-and-tested-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
With the input_configured() callback in place, the setup and frame
synchronization can be simplified. The input device initialization is
moved to mt_input_configured(), to make sure the full HID report has been
seen.
Reviewed-and-tested-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Add ELAN production request when resume.
Some Elan legacy devices require SET_IDLE to be set on resume.
It should be safe to send it to other devices too.
Tested on 3M, Stantum, Cypress, Zytronic, eGalax, and Elan panels.
Suggested by Benjamin Tissoires <benjamin.tissoires@enac.fr>
Signed-off-by: Scott Liu <scott.liu@emc.com.tw>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
A null test was left behind during the autoloading work;
the test was introduced by 8d179a9e, but was never completely
reverted.
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Zytronic panels shows a new way of setting the Input Mode feature.
This feature is put in the second usage in the HID feature, instead
of the first, as the majority of the multitouch devices.
This patch adds a detection step when the feature is presented to know
where the feature is located in the report. We can then trigger the right
command to the device. This removes the magic number "0" in the function
mt_set_input_mode.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Since Henrik's autoloading changes, the proper macro for device
entry is MT_USB_DEVICE().
Reported-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Add support for a Novatek touchscreen panel as a generic HID multitouch
panel.
Signed-off-by: Austin Hendrix <ahendrix@willowgarage.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>