Add support for Measurement Specialities MS5611 pressure
and temperature sensor.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Use common hid sensor iio pm functions. Also the poll time read and
wait is part of power up function of hid sensor iio pm function, so
remove from the client drivers.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The calculations for temperature and pressure compensation were already slightly
optimized in comparison to the datasheet. So, it makes sense to optimize even a
bit more, making proper use of C operators:
- variable t in bmp280_compensate_temp() can be eliminated by directly
returning the result of the relevant equation.
- make use of the += operator and eliminate an unnecessary parenthesis level in
bmp280_compensate_press().
When the initialization of the ctrl_meas register fails, the error message will
now mention the right register name.
During probe, i2c_set_clientdata() is called, although it is not necessary. Drop
it.
Signed-off-by: Hartmut Knaack <knaack.h@gmx.de>
Reviewed-by: Vlad Dogaru <vlad.dogaru@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This version of the code avoids extra memory copy operations and is
somewhat smaller in code size.
Signed-off-by: Vlad Dogaru <vlad.dogaru@intel.com>
Acked-by: Hartmut Knaack <knaack.h@gmx.de>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
According to the datasheet and as defined in struct bmp280_comp_press, dig_p1 is
of type u16, while dig_p2 to dig_p9 are of type s16. In
bmp280_read_compensation_press(), values read from the device were treated as
the wrong type.
In bmp280_read_press() the fractional part of the measured pressure is
calculated wrong. A better way is to use *val for the raw pressure and *val2 for
the quotient and let the core do the proper conversion using IIO_VAL_FRACTIONAL.
Signed-off-by: Hartmut Knaack <knaack.h@gmx.de>
Acked-by: Vlad Dogaru <vlad.dogaru@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch fix pressure data variable name. Usually pdata name
it is used for platform data.
Signed-off-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch change structure name and related variables names.
Signed-off-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch removes the .owner field for drivers which use the
platform_driver_register api because this is overriden in
_platform_driver_register.
Signed-off-by: Sanjeev Sharma <Sanjeev_Sharma@mentor.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The I2C devices that make up the STMicroelectronics MEMS sensors
may be sneakily enabled by cleverly giving the device node the same
name as a string match from the platform device ID table. However
the right method is to use the compatible string.
On detection, the ST sensors use the ID string to probe and
instatiate the right sensor driver, so pass the kernel-internal ID
string in the .data field of the OF match table, and set the I2C
client name to this name when a compatible match is used.
This avoids having misc Linux-specific strings floating around in
the device tree.
Cc: Lee Jones <lee.jones@linaro.org>
Cc: Denis CIOCCA <denis.ciocca@st.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored
the actual return values (which could be -EINVAL) and instead
returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value
obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO
upon success.
Agreed with by Srinivas.
Signed-off-by: Sachin Kamat <sachin.kamat@samsung.com>
Cc: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Jonathan writes:
First set of IIO fixes for the 3.16 cycle.
A mixed bag of fixes, many of which feel just to late for 3.15.
* hid sensors - some devices need a feature report request in order to
change power state. This isn't part of the spec, but has been observed
on several devices and does no harm to others.
* mpl3115 has had two errors in the buffer description fixed. The presure is
signed, not unsigned and the temperature has 12 bits rather than 16.
These could lead to incorrect interpretation of the data in userspace.
* tsl2x7x - the high byte of the proximity thresholds should be written along
with the low byte (which was). This could lead to interesting results
with large thresholds.
* twl4030 - a flag to specify processed values were required was not set
when initializing a reading. As such values returned were in an unknown
state. Fixed by simply initializing it appropriately.
* IIO_SIMPLE_DUMMY_BUFFER did not select IIO_BUFFER leading to randconfig
build errors.
* ak8975 was applying an unwanted le16_to_cpu conversion as the i2c framework
already performs one. As such for big endian systems, the bytes would be
in the wrong order in the magnetic field measurements reported.
* mxs-lradc - the controllable voltage dividers were not enabled / disabled for
later channels than the first one during conversion.
* at91_adc error handling returned -ENOMEM in a u8. Return value of
at91_adc_get_trigger_value_by_name changed to int thus allowing -ENOMEM and
also original values to be returned.
* mcb - mcb_request_mem returns and ERR_PTR but the caller was checking for
NULL to detect an error.
(i) pressure is 20-bit unsigned, not signed; the buffer description
is incorrect; for raw reads, this is just cosmetic
(ii) temperature is 12-bit signed, not 16-bit; this affects
readout of temperatures below zero as the sign bit is incorrectly
processed
reported via private mail
Cc: stable@vger.kernel.org
Signed-off-by: Peter Meerwald <pmeerw@pmeerw.net>
Reported-by: Robert Deliƫn <robert@delien.nl>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Added support for raw reading of channel. If the sensor is powered
off, it will turn on for reading value.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Added an API to allow client drivers to turn ON and OFF sensors for
quick read. Added data_read as counting varaible instead of boolean,
so that sensor is powered off only when last user released it.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Currently the pressure sensor has code to retrieve and enable two
regulators for Vdd and Vdd IO, but actually these voltage inputs
are found on all of these ST sensors, so move the regulator
handling to the core and make sure all the ST sensors call these
functions on probe() and remove() to enable/disable power.
Here also mover over to obtaining the regulator from the *parent*
device of the IIO device, as the IIO device is created on-the-fly
in this very subsystem it very unlikely evert have any regulators
attached to it whatsoever. It is much more likely that the parent
is a platform device, possibly instantiated from a device tree,
which in turn have Vdd and Vdd IO supplied assigned to it.
Cc: Lee Jones <lee.jones@linaro.org>
Cc: Denis CIOCCA <denis.ciocca@st.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>