There is no need to allocate heap for reply only to copy stack data to
it. This also fix rp memory leak and missing hdev unlock if kmalloc
failed.
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Increment the mgmt revision due to the recently added
Read Extended Controller Information and Set Appearance commands.
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch enables prepending appearance value to scan response data.
It also adds support for setting appearance value through mgmt command.
If currently advertised instance has apperance flag set it is expired
immediately.
Signed-off-by: Michał Narajowski <michal.narajowski@codecoup.pl>
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch enables appending local name to scan response data. If
currently advertised instance has name flag set it is expired
immediately.
Signed-off-by: Michał Narajowski <michal.narajowski@codecoup.pl>
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Use kzalloc rather than kmalloc followed by memset with 0.
Generated by: scripts/coccinelle/api/alloc/kzalloc-simple.cocci
Signed-off-by: Wei Yongjun <weiyongjun1@huawei.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
A comment in the code states that SCO connection should be rejected
with the proper error value between 0xd-0xf. The code uses
HCI_ERROR_REMOTE_LOW_RESOURCES which is 0x14.
This led to following error:
< HCI Command: Reject Synchronous Co.. (0x01|0x002a) plen 7
Address: 34:51:C9:EF:02:CA (Apple, Inc.)
Reason: Remote Device Terminated due to Low Resources (0x14)
> HCI Event: Command Status (0x0f) plen 4
Reject Synchronous Connection Request (0x01|0x002a) ncmd 1
Status: Invalid HCI Command Parameters (0x12)
Instead make use of HCI_ERROR_REJ_LIMITED_RESOURCES which is 0xd.
Signed-off-by: Frédéric Dalleau <frederic.dalleau@collabora.co.uk>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When closing HCI User Channel, the New Settings event was send out to
inform about changed settings. However such event is wrong since the
exclusive HCI User Channel access is active until the Index Added event
has been sent.
@ USER Close: test
@ MGMT Event: New Settings (0x0006) plen 4
Current settings: 0x00000ad0
Bondable
Secure Simple Pairing
BR/EDR
Low Energy
Secure Connections
= Close Index: 00:14:EF:22:04:12
@ MGMT Event: Index Added (0x0004) plen 0
Calling __mgmt_power_off from hci_dev_do_close requires an extra check
for an active HCI User Channel.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When opening and closing HCI user channel, send monitoring messages to
be able to trace its behavior.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This adds device class, complete local name and short local name
to EIR data in Extended Controller Info as specified in docs.
Signed-off-by: Michał Narajowski <michal.narajowski@codecoup.pl>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This command is used to retrieve the current state and basic
information of a controller. It is typically used right after
getting the response to the Read Controller Index List command
or an Index Added event (or its extended counterparts).
When any of the values in the EIR_Data field changes, the event
Extended Controller Information Changed will be used to inform
clients about the updated information.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Michał Narajowski <michal.narajowski@codecoup.pl>
In case an unbound HCI raw socket is later on bound, ensure that the
monitor notification messages indicate a close and re-open. None of
the userspace tools use the socket this, but it is actually possible
to use an ioctl on an unbound socket and then later bind it.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When opening and closing HCI raw sockets their main usage is for legacy
userspace. To track interaction with the modern mgmt interface, send
open and close monitoring messages for these action.
The HCI raw sockets is special since it supports unbound ioctl operation
and for that special case delay the notification message until at least
one ioctl has been executed. The difference between a bound and unbound
socket will be detailed by the fact the HCI index is present or not.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The control open and close monitoring events require special channel
checks to ensure messages are only send when the right events happen.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Assignment of the hci_pi(sk)->channel should be done early when binding
the HCI socket. This avoids confusion with the RAW channel that is used
for legacy access.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Only when the cookie has been assigned, then send the open and close
monitor messages. Also if the socket is bound to a device, then include
the index into the message.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of keeping a version string around, use version and revision
numbers and then stringify them for use as module parameter.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>