It makes no sense to attempt to manually configure the fan in auto mode,
or set the duty cycle directly in closed loop mode. The corresponding
registers are then read-only. If the user tries it nonetheless, error out
with EINVAL instead of silently doing nothing.
Signed-off-by: Nikolaus Schulz <mail@microschulz.de>
[guenter.roeck@ericsson.com: Minor formatting cleanup]
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
The F75387 supports automatic fan control using either PWM duty cycle or
RPM speed values. Make the driver detect the latter mode, and expose the
different modes in sysfs as per pwm_enable, so that the user can switch
between them.
The interpretation of the pwm_enable attribute for the F75387 is adjusted
to be a superset of those values used for similar Fintek chips which do
not support automatic duty mode, with 2 mapping to automatic speed mode,
and moving automatic duty mode to the new value 4.
Toggling the duty mode via pwm_enable is currently denied for the F75387,
as the chip then simply reinterprets the fan configuration register values
according to the new mode, switching between RPM and PWM units, which
makes this a dangerous operation.
This patch introduces a new pwm mode into the driver. This is necessary
because the new mode (automatic pwm mode, 4) may already be enabled by the
BIOS, and the driver should not break existing functionality. This was seen
on at least one board.
Signed-off-by: Nikolaus Schulz <mail@microschulz.de>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
For the F75387, the register holding the current PWM duty cycle value is
r/o; changing it requires writing to the fan expect register instead.
Signed-off-by: Nikolaus Schulz <mail@microschulz.de>
[guenter.roeck@ericsson.com: Simplified function parameters]
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Temperature history is reset by writing 0x8000 into the peak temperature
register, not 0xffff.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Acked-by: Jean Delvare <khali@linux-fr.org>
By hwmon sysfs interface convention, setting pwm_enable to zero sets a fan
to full speed. In the f75375s driver, this need be done by enabling
manual fan control, plus duty mode for the F875387 chip, and then setting
the maximum duty cycle. Fix a bug where the two necessary register writes
were swapped, effectively discarding the setting to full-speed.
Signed-off-by: Nikolaus Schulz <mail@microschulz.de>
Cc: Riku Voipio <riku.voipio@iki.fi>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
An error while creating sysfs attribute files in the driver's probe function
results in an error abort, but already created files are not removed. This patch
fixes the problem.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Cc: stable@vger.kernel.org # 3.0+
Cc: Dirk Eibach <eibach@gdsys.de>
Acked-by: Jean Delvare <khali@linux-fr.org>
Initialize PPR register for both channels, and set correct PPR register bits.
Also remove unnecessary variable initializations.
Signed-off-by: Chris D Schimp <silverchris@gmail.com>
[guenter.roeck@ericsson.com: Merged two patches into one]
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Cc: stable@vger.kernel.org # 3.0+
Acked-by: Roland Stigge <stigge@antcom.de>
RPM calculation from tachometer value does not depend on PPR.
Also, do not report negative RPM values.
Signed-off-by: Chris D Schimp <silverchris@gmail.com>
[guenter.roeck@ericsson.com: do not report negative RPM values]
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Cc: stable@vger.kernel.org # 3.0+
Acked-by: Roland Stigge <stigge@antcom.de>
Treat pwmX as a measured value, not as a (mostly static) limit value, so
that it is updated more frequently from the device register.
Signed-off-by: Nikolaus Schulz <mail@microschulz.de>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Unlike the other chips supported by this driver, the F75387 stores the
pwm_mode in register F75375_REG_FAN_TIMER, not F75375_REG_CONFIG1.
Signed-off-by: Nikolaus Schulz <mail@microschulz.de>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
In order to enable temperature mode aka automatic mode for the F75373 and
F75375 chips, the two FANx_MODE bits in the fan configuration register
need be set to 01, not 10.
Signed-off-by: Nikolaus Schulz <mail@microschulz.de>
Cc: stable@kernel.org # 2.6.32+
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
NCT6776F can select fan input pins for fans 3 to 5 with a secondary set of
chip register bits. Check that second set of bits in addition to the first set
to detect if fans 3..5 are monitored.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Cc: stable@vger.kernel.org # 3.0+
Acked-by: Jean Delvare <khali@linux-fr.org>
Properly clamp temperature limits set by the user. Without this fix,
attempts to write temperature limits above the maximum supported by
the chip (255 degrees Celsius) would arbitrarily and unexpectedly
result in the limit being set to 0 degree Celsius.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: stable@vger.kernel.org
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Fix almost all coding style issues except for the multi-line macro errors,
which do not really apply since the macros are not multi-line statements
but declarations.
Based on merged patch series from Zac Storer; fixed remaining checkpatch
errors and warnings.
Cc: Zac Storer <zac.3.14159@gmail.com>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Until we get a datasheet for the IT8728F, treat it as fully compatible
with the IT8721F, as it seems to work reasonably well.
This closes kernel bug #27262.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Acked-by: Guenter Roeck <guenter.roeck@ericsson.com>
When writing the update_interval attribute, the parameter value was
not range checked, which could cause an integer overflow and result
in an arbitrary update interval. Fix by limiting the value range to
<0, 100000>.
Reported-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
The LM63 and compatible devices have a lookup table to control the fan
speed automatically. Expose it in sysfs. Values are cached for 5
seconds, independently of the other register values to avoid slowing
down "sensors". We might make the table values writable in the future.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Tested-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Guenter Roeck <guenter.roeck@ericsson.com>