Commit Graph

47 Commits

Author SHA1 Message Date
Kyle McMartin 67a061a191 [PARISC] Add os_id_to_string helper
Add a helper to asm/pdc.h to translate OS_ID values to strings
and use it in the pdc_stable driver.

Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-06-27 23:28:43 +00:00
Kyle McMartin ec1fdc24c2 [PARISC] OS_ID_LINUX == 0x0006
We were assigned an OS_ID of 0x0006. Consistently use OS_ID_LINUX
instead of using the magic number. Also update the OS_ID_ defines in
asm/pdc.h to reflect this.

Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-06-27 23:28:42 +00:00
Thibaut Varene b0e8bfca2f [PARISC] Reduce data footprint in pdc_stable.c
No code change - reduce data footprint.

Signed-off-by: Thibaut VARENE <varenet@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-06-27 23:28:39 +00:00
Thibaut Varene 3f9edb53f7 [PARISC] pdc_stable version 0.30
pdc_stable v0.30:

This patch introduces 3 more files to the /sys/firmware/stable tree:
- diagnostic, which contains a cryptic hex string
- osdep1, a 16 bytes os-dependent storage area always available
- osdep2, another os-dependent storage area which existence/size depends
on hversion.

This patch also adds code to setup the "Linux" signature in stable
storage. That is to say that starting with this patch, the kernel will
now sign its OSID (0x0006, thx LaMont) in Stable Storage upon boot,
whether pdc_stable is enabled or not.

Signed-off-by: Thibaut VARENE <varenet@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-06-27 23:28:38 +00:00
Thibaut Varene 8ffaeaf42e [PARISC] PDC_CHASSIS is implemented on all machines
This patch removes a limitation of the original code, so that CHASSIS
codes can be sent to all machines. On machines with a LCD panel, this
code displays "INI" during bootup, "RUN" when the system is booted and
running, "FLT" when a panic occurs, etc.

This part of the code can be enabled/disabled through CONFIG_PDC_CHASSIS

This patch also adds minimalistic support for Chassis warnings, through
a proc entry '/proc/chassis', which will reflect the warnings status (PSU
or fans failure when they happen, NVRAM battery level and temperature
thresholds overflows).

This part of the code can be enabled/disabled through CONFIG_PDC_CHASSIS_WARN

Signed-off-by: Thibaut VARENE <varenet@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-06-27 23:28:37 +00:00
Kyle McMartin 692086e0b3 [PARISC] Test ioc_needs_fdc variable instead of open coding
Some debugging code in sba_iommu.c should be testing ioc_needs_fdc,
not directly testing boot_cpu_data.

Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-06-27 23:28:35 +00:00
Grant Grundler 40d78de1ac [PARISC] Fix gcc 4.1 warnings in sba_iommu.c
Clean up gcc 4.1 warnings noted by Joel Soete.
Kyle McMartin gets kudos for pointing out the issues.
Matthew Wilcox noticed sba_iommu was using open coded versions
of (read|write)X.

Signed-off-by: Grant Grundler <grundler@parisc-linux.org>
Signed-off-by: Matthew Wilcox <willy@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-06-27 23:28:34 +00:00
Grant Grundler b312c33e36 [PARISC] Document that we tolerate "Relaxed Ordering"
This means "DMA Read returns" can bypass "MMIO Writes".
Violating the PCI specs in this case improves outbound DMA "flows"
and is currently not required by any drivers.

This is NOT a new behavior. Previous chipsets did this
already and I believe ZX1 PDC was already setting this
for hpux. I just want to further document the behavior.

Signed-off-by: Grant Grundler <grundler@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-04-21 22:20:33 +00:00
Helge Deller 67a5a59d33 [PARISC] Misc. janitorial work
Fix a spelling mistake, add a KERN_INFO flag, and fix some whitespace
uglies.

Signed-off-by: Helge Deller <deller@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-04-21 22:20:32 +00:00
Helge Deller 5076c15862 [PARISC] I/O-Space must be ioremap_nocache()'d
Addresses in F-space must be accessed uncached on most parisc machines.

Signed-off-by: Helge Deller <deller@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-03-30 17:48:42 +00:00
Thibaut VARENE a81dd18eb9 [PARISC] Clarify pdc_stable license terms
pdc_stable.c is explicitly licensed under GPL version 2.

Signed-off-by: Thibaut VARENE <varenet@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-03-30 17:48:41 +00:00
Alan Stern e041c68341 [PATCH] Notifier chain update: API changes
The kernel's implementation of notifier chains is unsafe.  There is no
protection against entries being added to or removed from a chain while the
chain is in use.  The issues were discussed in this thread:

    http://marc.theaimsgroup.com/?l=linux-kernel&m=113018709002036&w=2

We noticed that notifier chains in the kernel fall into two basic usage
classes:

	"Blocking" chains are always called from a process context
	and the callout routines are allowed to sleep;

	"Atomic" chains can be called from an atomic context and
	the callout routines are not allowed to sleep.

We decided to codify this distinction and make it part of the API.  Therefore
this set of patches introduces three new, parallel APIs: one for blocking
notifiers, one for atomic notifiers, and one for "raw" notifiers (which is
really just the old API under a new name).  New kinds of data structures are
used for the heads of the chains, and new routines are defined for
registration, unregistration, and calling a chain.  The three APIs are
explained in include/linux/notifier.h and their implementation is in
kernel/sys.c.

With atomic and blocking chains, the implementation guarantees that the chain
links will not be corrupted and that chain callers will not get messed up by
entries being added or removed.  For raw chains the implementation provides no
guarantees at all; users of this API must provide their own protections.  (The
idea was that situations may come up where the assumptions of the atomic and
blocking APIs are not appropriate, so it should be possible for users to
handle these things in their own way.)

There are some limitations, which should not be too hard to live with.  For
atomic/blocking chains, registration and unregistration must always be done in
a process context since the chain is protected by a mutex/rwsem.  Also, a
callout routine for a non-raw chain must not try to register or unregister
entries on its own chain.  (This did happen in a couple of places and the code
had to be changed to avoid it.)

Since atomic chains may be called from within an NMI handler, they cannot use
spinlocks for synchronization.  Instead we use RCU.  The overhead falls almost
entirely in the unregister routine, which is okay since unregistration is much
less frequent that calling a chain.

Here is the list of chains that we adjusted and their classifications.  None
of them use the raw API, so for the moment it is only a placeholder.

  ATOMIC CHAINS
  -------------
arch/i386/kernel/traps.c:		i386die_chain
arch/ia64/kernel/traps.c:		ia64die_chain
arch/powerpc/kernel/traps.c:		powerpc_die_chain
arch/sparc64/kernel/traps.c:		sparc64die_chain
arch/x86_64/kernel/traps.c:		die_chain
drivers/char/ipmi/ipmi_si_intf.c:	xaction_notifier_list
kernel/panic.c:				panic_notifier_list
kernel/profile.c:			task_free_notifier
net/bluetooth/hci_core.c:		hci_notifier
net/ipv4/netfilter/ip_conntrack_core.c:	ip_conntrack_chain
net/ipv4/netfilter/ip_conntrack_core.c:	ip_conntrack_expect_chain
net/ipv6/addrconf.c:			inet6addr_chain
net/netfilter/nf_conntrack_core.c:	nf_conntrack_chain
net/netfilter/nf_conntrack_core.c:	nf_conntrack_expect_chain
net/netlink/af_netlink.c:		netlink_chain

  BLOCKING CHAINS
  ---------------
arch/powerpc/platforms/pseries/reconfig.c:	pSeries_reconfig_chain
arch/s390/kernel/process.c:		idle_chain
arch/x86_64/kernel/process.c		idle_notifier
drivers/base/memory.c:			memory_chain
drivers/cpufreq/cpufreq.c		cpufreq_policy_notifier_list
drivers/cpufreq/cpufreq.c		cpufreq_transition_notifier_list
drivers/macintosh/adb.c:		adb_client_list
drivers/macintosh/via-pmu.c		sleep_notifier_list
drivers/macintosh/via-pmu68k.c		sleep_notifier_list
drivers/macintosh/windfarm_core.c	wf_client_list
drivers/usb/core/notify.c		usb_notifier_list
drivers/video/fbmem.c			fb_notifier_list
kernel/cpu.c				cpu_chain
kernel/module.c				module_notify_list
kernel/profile.c			munmap_notifier
kernel/profile.c			task_exit_notifier
kernel/sys.c				reboot_notifier_list
net/core/dev.c				netdev_chain
net/decnet/dn_dev.c:			dnaddr_chain
net/ipv4/devinet.c:			inetaddr_chain

It's possible that some of these classifications are wrong.  If they are,
please let us know or submit a patch to fix them.  Note that any chain that
gets called very frequently should be atomic, because the rwsem read-locking
used for blocking chains is very likely to incur cache misses on SMP systems.
(However, if the chain's callout routines may sleep then the chain cannot be
atomic.)

The patch set was written by Alan Stern and Chandra Seetharaman, incorporating
material written by Keith Owens and suggestions from Paul McKenney and Andrew
Morton.

[jes@sgi.com: restructure the notifier chain initialization macros]
Signed-off-by: Alan Stern <stern@rowland.harvard.edu>
Signed-off-by: Chandra Seetharaman <sekharan@us.ibm.com>
Signed-off-by: Jes Sorensen <jes@sgi.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2006-03-27 08:44:50 -08:00
Eric Sesterhenn b74945547f BUG_ON() Conversion in drivers/parisc/
this changes if() BUG(); constructs to BUG_ON() which is
cleaner, contains unlikely() and can better optimized away.

Signed-off-by: Eric Sesterhenn <snakebyte@gmx.de>
Signed-off-by: Adrian Bunk <bunk@stusta.de>
2006-03-24 18:52:10 +01:00
Kyle McMartin 7ec14e49b7 [PARISC] Convert sba_iommu.c to use seq_file
Use seq_file interface for proc output in sba_iommu. Also
clean up the bus root assignment, and give the proc files
a more logical name. Tested on my J6000.

Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-02-08 22:56:22 -05:00
Kyle McMartin f823bcae2b [PARISC] Convert ccio-dma.c to use seq_file
Gut ccio-dma.c of the ugly proc append and snprintf cruft and
just use seq_printf instead. Tested on a K-class.

Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-02-08 22:56:16 -05:00
Kyle McMartin 16541c8745 [PARISC] Clean up printk in superio.c
Clean up some of the messages printed by the superio driver
by defining a prefix instead of duplicating it in every message.
Also some small coding style cleanups.

Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-22 20:26:57 -05:00
Kyle McMartin 85509c0007 [PARISC] Add chassis_power_off routine
Define a chassis_power_off routine that machines which have a way
to turn off the power supply can hook into. Formerly they were
using pm_power_off, which is now being used by generic code. Make
lasi.c use chassis_power_off instead of pm_power_off.

Note, all machines need to call machine_power_off so that the
switch can power off the machine, though halt -p may not necessarily
be able to work properly on the machine.

Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-22 20:26:50 -05:00
Thibaut VARENE c742842223 [PARISC] pdc_stable version 0.22
pdc_stable v0.22, changes since v0.10:

  o renamed root subsystem from 'pdc' to 'stable'
  o split 'info' into several files, one per PDC field
  o implemented 'autoboot' and 'autosearch' write calls to toggle
    these flags
  o grant read permission to all users on "safe" files
  o more code cleanup (removed duplicate code)
  o avoid bad stable storage clobbering by write locking critical sections
  o print consistent data as well
  o SMP cleanups

Signed-off-by: Thibaut VARENE <varenet@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-22 20:26:35 -05:00
Helge Deller cb6fc18e9c [PARISC] Use kzalloc and other janitor-style cleanups
Helge,
  o Convert a bunch of kmalloc/memset uses to kzalloc.
  o pci.c: Add some __read_mostly annotations.
  o pci.c: Move constant pci_post_reset_delay to asm/pci.h
  o grfioctl.h: Add A4450A to comment of CRT_ID_VISUALIZE_EG.
  o Add some consts to perf.c/perf_images.h

Matthew,
  o sticore.c: Add some consts to suppress compile warnings.

Signed-off-by: Helge Deller <deller@parisc-linux.org>
Signed-off-by: Matthew Wilcox <willy@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-22 20:26:31 -05:00
Randy.Dunlap c59ede7b78 [PATCH] move capable() to capability.h
- Move capable() from sched.h to capability.h;

- Use <linux/capability.h> where capable() is used
	(in include/, block/, ipc/, kernel/, a few drivers/,
	mm/, security/, & sound/;
	many more drivers/ to go)

Signed-off-by: Randy Dunlap <rdunlap@xenotime.net>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2006-01-11 18:42:13 -08:00
Matthew Wilcox f45adcf977 [PARISC] Fix Dino reporting on J2240
Fix Dino reporting on J2240. This particular machine thought it
had a Cujo. Also add J2240 Dino chip to the hp_hardware_list.

Signed-off-by: Matthew Wilcox <willy@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-10 21:53:14 -05:00
Thibaut VARENE 4b991da7fe [PARISC] pdc_stable: More robust sysfs error checking
pdc_stable 0.10:
As mentioned on LKML, pdc_stable wasn't checky enough on the return
values of some calls. This patch makes it more robust to errors when
registering objects in sysfs.

Signed-off-by: Thibaut VARENE <varenet@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-10 21:52:36 -05:00
Grant Grundler 6ca45a24cc [PARISC] Truncate overlapping PAT PDC reported ranges
Deal with overlapping LBA MMIO resources,

rp3440 PDC BUG: PDC reports lmmio range for the last rope that overlaps
with the CPU HPA. Console output was:

...
Found devices:
1. Storm Peak Fast at 0xfffffffffe798000 [152] { 0, 0x0, 0x889, 0x00004 }
2. Storm Peak Fast at 0xfffffffffe799000 [153] { 0, 0x0, 0x889, 0x00004 }
...
FAILED: lba_fixup_bus() request for lmmio_space
[fffffffff0000000/fffffffffecffffe]

Output is now:

LBA: Truncating lmmio_space [fffffffff0000000/fffffffffecffffe] to
[fffffffff0000000,fffffffffe797fff]

My only concern with this patch is how C8000 (PAT PDC) will report
elmmio ranges when a gfx card is installed. I'll have to test this
another day.

Signed-off-by: Grant Grundler <grundler@parisc-linux.org>
Signed-off-by: James Bottomley <jejb@parisc-linux.org>
Signed-off-by: Matthew Wilcox <willy@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-10 21:52:04 -05:00
Helge Deller 4d64c9f58e [PARISC] Introduce DINO_LOCAL_IRQS and use it for gsc_find_local_irq
Fix dino by using DINO_LOCAL_IRQS as the limit for gsc_find_local_irq()
instead of the irq itself.

Signed-off-by: Helge Deller <deller@parisc-linux.org>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-10 21:51:39 -05:00
Alexey Dobriyan 45dbe9147d [PARISC] Add __user annotation to eisa_eeprom.c
Annotate eisa_eeprom_read() with __user.

Signed-off-by: Alexey Dobriyan <adobriyan@gmail.com>
Signed-off-by: Matthew Wilcox <matthew@wil.cx>
Signed-off-by: Kyle McMartin <kyle@parisc-linux.org>
2006-01-10 21:51:18 -05:00