edac: remove arch-specific parameter for the error handler

Remove the arch-dependent parameter, as it were not used,
as the MCE tracepoint weren't implemented. It probably doesn't
make sense to have an MCE-specific tracepoint, as this will
cost more bytes at the tracepoint, and tracepoint is not free.

The changes at the EDAC drivers were done by this small perl script:

	$file .=$_ while (<>);
	$file =~ s/(edac_mc_handle_error)\s*\(([^\;]+)\,([^\,\)]+)\s*\)/$1($2)/g;
	print $file;

Signed-off-by: Mauro Carvalho Chehab <mchehab@redhat.com>
This commit is contained in:
Mauro Carvalho Chehab
2012-06-04 11:29:25 -03:00
parent 075f30901e
commit 03f7eae80f
28 changed files with 73 additions and 86 deletions
+2 -2
View File
@@ -452,7 +452,7 @@ static void i7300_process_fbd_error(struct mem_ctl_info *mci)
edac_mc_handle_error(HW_EVENT_ERR_FATAL, mci, 0, 0, 0,
branch, -1, rank,
is_wr ? "Write error" : "Read error",
pvt->tmp_prt_buffer, NULL);
pvt->tmp_prt_buffer);
}
@@ -499,7 +499,7 @@ static void i7300_process_fbd_error(struct mem_ctl_info *mci)
syndrome,
branch >> 1, channel % 2, rank,
is_wr ? "Write error" : "Read error",
pvt->tmp_prt_buffer, NULL);
pvt->tmp_prt_buffer);
}
return;
}